Response
: The service required LED on the chassis and on the affected
FRU may be illuminated.
Impact
: No SP impact.
Action
: The administrator should review the fault on the Host OS.
Please refer to the Details section of the Knowledge Article
for additional information.
2. Compruebe si hay errores en el host.
# fmadm fault
#
3. Verifique que el error que se muestra en Oracle ILOM se haya reparado en el host.
# fmdump
TIME
Sep 16 08:38:19.5582 af875d87-433e-6bf7-cb53-c3d665e8cd09 SUN4V-8002-6E
Sep 16 08:40:47.8191 af875d87-433e-6bf7-cb53-c3d665e8cd09 FMD-8000-4M Repaired
Sep 16 08:40:47.8446 af875d87-433e-6bf7-cb53-c3d665e8cd09 FMD-8000-6U Resolved
#
4. Vacíe la memoria caché de recursos del host para eliminar el componente que
anteriormente presentaba defectos.
# fmadm flush /SYS/MB
fmadm: flushed resource history for /SYS/MB
#
5. Repare el error en Oracle ILOM.
faultmgmtsp> fmadm repair /SYS/MB
faultmgmtsp> fmadm faulty
No faults found
faultmgmtsp>
24
Notas del producto del servidor SPARC T4-2 • Diciembre de 2011
Check the Host OS for more information.
<-- Host displays no faults
UUID
SUNW-MSG-ID