Installation Conditions; Quick Start; Status Indication - alfen Eve Mini Guía De Instalación Rápida

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
This document contains installation instructions
for the Eve Mini. Please always refer to our
website for the most up-to-date and complete
manual for the product.
https://alfen.com/en/downloads

Installation conditions

The installation must comply with standards
and (local) regulations and must only be carried
out by an Alfen qualified technician.
Conditions of use
Operating temperature
-25 °C / +40 °C
Relative humidity
5% / 95%
Electrical safety class
I
Protection rating
IP55
Mechanical impact
IK10
Nominal input voltage
Single-phase
230 V ± 10%
50 Hz
3-phase
400 V ± 10%
50 Hz
Short-circuit protection (system circuit breaker)
Single-phase
3-phase
1x 20 A, 1P,
1x 20 A, 3P,
16 A
char. B or C
char. B or C
1x 40 A, 1P,
1x 40 A, 3P,
32 A
char. B or C
char. B or C
Short-circuit protection (cartridge fuses)
Single-phase
3-phase
16 A
1x 20 A gG
3x 20 A gG
32 A
1x 35 A gG
3x 35 A gG
Residual current device
Single-phase
3-phase
16 A
Type A or B, 30 mA, 20 A
32 A
Type A or B, 30 mA, 40A
Earthing
TN system
PE cable
self-installed earth electrode,
TT system
< 100 ohms earth dispersion
resistance
Minimum cable diameters
(for max. length of 50 m)
Single-phase
3-phase
2
16 A
3x 4 mm
5x 4 mm
2
32 A
3x 6 mm
5x 6 mm
6
5
7
8
9
2
2
4
Installing
1
Remove the front cover.
1
Place the Eve Mini with the front cover facing
downwards.
Use the box as a base, to avoid damaging the
Eve Mini.
Remove the mounting bracket.
Unscrew the six T20 screws.
Turn the Eve Mini over again.
Pull the front cover straight upwards.
For wall mounting only:
2
Fit the mounting bracket.
Drill the holes.
Use the mounting bracket as a template to mark
2
3
the holes.
Fit the wall plugs.
Secure the mounting bracket with the 4 screws.
Ensure the wall plugs and screws are suitable
for the type of wall.
3
Fit the Eve Mini.
Position the Eve Mini on the mounting bracket or
mounting pole.
Do not drop the Eve Mini. Keep hold of the Eve
Mini with one hand.
Tighten the four M8 x 12 mm screws.
Fit the earth cable under the bottom right-hand
4
5
6
7
side screw.
4
Remove the frame and the plug connection.
Unscrew the 3 screws.
Do not damage the power cables. Leave the
frame hanging carefully next to the housing.
For control management via SIM only:
5
Fit the SIM card.
power cable
charging cable
For control management via the internet only:
ethernet cable
6
Connect the ethernet cable.
Feed the cable through the gland.
8
9
Connect the cable.
Tighten the gland.
Ensure the cable is clamped firmly in the gland.
Only then will the IP55 sealing be effective.
7
Connect the power cable.
Make sure the power cable is not live.
L3
Feed the cable through the gland.
L2
Connect the cores to the terminals.
Tighten the gland.
L1
N
Ensure the cable is clamped firmly in the gland.
Only then will the IP55 sealing be effective.

Quick start

Only for model with charging cable:
8
Connect the charging cable.
9
Connect the CP cable.
Feed the cable through the gland.
Connect the cores to the terminals.
Ensure the phases are connected to the correct
terminals.
Connect the CP cable to the connector.
Tighten the gland.
Ensure the cable is clamped firmly in the gland.
Only then will the IP55 sealing be effective.
10 Refit the socket.
Tighten the 3 screws.
Take care not to damage the cables; keep them
clear of the locking mechanism so they do not
obstruct it.
11 Refit the front cover.
Place the front cover on the housing.
Tighten the six T20 screws on the back.
Avoid dropping the front cover. Keep hold of
the front cover with one hand.

Status indication

Model with display
Charging pass accepted, cable connected.
Communicating with vehicle, or charged
and ready to use.
Charging transaction active, with indication
of charging rate.
Error message, with error code.
Model with LED indication
Charging pass accepted,
Green
cable connected.
Communication with
Cyan
vehicle, or charged and
ready to use.
Blue
Charging transaction
(steady)
active.
Blue
Load balancing activated.
(flashing)
Charging at reduced rate.
Blue-Cyan
Load balancing activated.
(alternating)
Charging paused.
Red
Error message.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido