Liability Exclusion; Replacing The Filter Cartridge - Brita PURITY 1200 Clean Instrucciones De Sustitución

Ocultar thumbs Ver también para PURITY 1200 Clean:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
1 Cartridge Replacement Instructions
Before replacing the filter, read the manual on the PURITY 1200 Clean/PURITY 1200 Clean Extra
filter system. There, you will find detailed information on operating and safety notes, filter capacity,
maintenance, troubleshooting and technical data.

2 Liability exclusion

The filter must be replaced exactly in accordance with the information in these replacement instructions.
BRITA shall not be liable for any damage, including consequential damage, that may occur as a result
of not observing these replacement instructions or carrying them out incorrectly.

3 Replacing the Filter Cartridge

Caution: Filter replacement and maintenance of the filter system may be carried out only by
!
specialist staff.
Caution: The PURITY replacement cartridge may only be used in combination with the pressure
!
vessel that has been specifically designed for its size. See page 3.
The filter cartridge must be replaced after 6–12 months, at the latest 12 months after commissioning,
irrespective of the level of exhaustion of the filter system. If the capacity of the filter cartridge has
already been exhausted, it must be replaced earlier.
Caution: During the exchange, carefully examine all dismantled parts! Faulty parts must be
!
exchanged, dirty parts cleaned! Before replacing, read the Operating and Safety Instructions in
Chapter 3 of the manual. After the product has been stored at tempera tures below 0°C, it must be
stored with the original packaging open at the ambient temperature of the place of installation for
at least 24 hours before entering use.
4 Removing the filter cartridge
Switch off the electrical power supply of the terminal equipment.
Close the inlet valve
Place the flush hose in a bucket and remove pressure from the filter system by open ing the
flush valve
. Collect waste water in a bucket.
16
Note: If the waste water is more than 1 litre, the inlet value
blocked with scale.
Lock the used filter cartridge
return in the original packaging to the appropriate BRITA address listed on the back of the cover.
at the inlet hose
6
Stand on the kick loops
lid
by pressing the lock
3
Place the pressure vessel lid
Stand on the kick loops
anti-clockwise by the mantle handles
1
Take your feet off the kick loops
with both hands on the mantle handles
Remove used filter cartridge
Place the used filter cartridge
for drainage (> 5 min).
with the transport protection cap
2
.
5
is not completely closed or is
6
with both feet while opening the pressure vessel
9
and turning it anti-clockwise as far as it will go.
8
vertically on the lid handle
3
with both feet while turning the pressure vessel
9
as far as it will go.
11
and press the pressure vessel
9
.
11
from the pressure vessel
2
in the sink with the connection facing down
2
.
14
1
.
1
of the new filter cartridge and
12
EN
down
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity 1200 clean extra

Tabla de contenido