Assemble nozzle packet
1 O ring
2 Rotation arm
3 Nozzle
4 Union joint
Inser the O ring in the nut of the rotation
arm.
Place the nozzle on it.
Slightly fasten the nozzle with the Union
joint.
Note:
The exit jet must be directed parallel to the
rotation arm.
Adjust the wrench area of the nozzle
(width 10) so that it is parallel to the ro-
tation arm.
Tighten the Union joint (width 22) using
a wrench.
Floor cleaning
Connect the steel pipe of the high pres-
sure cleaner to the FR 30 and tighten it
with wrenches (width 24).
During breaks in working, tilt the hand
spray gun with spray pipe towards the
front. The appliance is then in its park-
ing position.
– 2
EN