3¼" X 10"
HORIZONTAL
KNOCKOUT
PLATE
14
DUCTED INSTALLATION ONLY:
Remove 3¼" x 10 vertical or 3¼" x 10" horizontal
knockout plate as appropriate for your ducting method.
15
DUCTED INSTALLATION ONLY:
Attach 3¼" x 10" Damper/Duct Connector over the
knockout opening.
NOTE To accommodate off-center ductwork, the 3¼" x 10"
damper/duct connector can be installed up to 3/8" on
either side of the hood center.

INSTALL THE HOOD

WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
16
Remove Electrical Wiring Box Cover from inside of hood.
3¼" X 10"
VERTICAL
KNOCKOUT
PLATE
3¼" X 10" DAMPER / DUCT
CONNECTOR
ELECTRICAL WIRING
BOX COVER
ELECTRICAL
POWER
CABLE
KNOCKOUT
Remove appropriate Electrical Power Cable Knockout
17
from top or back of hood.
HOUSE
POWER CABLE
Run House Power Cable between service panel
18
and hood location. Attach power cable to hood using
appropriate clamp.
19
Hang hood from (4) mounting screws driven part-way into
cabinet locations (shown in illustrations under "PREPARE
HOOD LOCATION"). Mounting screws are included in
parts bag. Slide hood back towards wall until mounting
screw heads are engaged in narrow end of keyhole slots
in top of hood. Tighten screws securely.
DUCTED INSTALLATION ONLY:
20
Connect ductwork to hood and use duct tape to make
joints secure and air-tight. Make sure the damper / duct
connector enters the ductwork and that the damper
opens and closes freely.
MODEL QB130SS
Page 5