Make holes for cables and to fix a camera.
For camera fixing, four of 3.8mmø holes are needed.
For the hole for cable, a diameter of the opening should be at least 50mm to
60mm. Please make it with utmost care not to give damage to wires.
Holes for camera fixing

4-2. Mounting the camera (Ceiling)

(1) Put a rubber sealing gasket on the housing base, paying attention to allow for
the screw holes.
(2) Take the clear dome cover off by loosening the three screws with the supplied
hex-wrench (Hexlobe).
(3) Remove the camera unit to access fixing holes on the housing base, by loosening
fixing screws of the camera unit.
(4) Install the main unit to the ceiling with supplied two screws among four.
The remaining two screws will be used later.
Before fix the main unit, pass the wiring through the hole of 50mm to 60mm
diameter drilled at the previous step 4-1.
(5) After taking out the camera unit by loosening the camera unit fixing screws, fix
the housing to the ceiling with remaining two screws. In this process, please be
careful not to damage any cables.
(6) Refit the camera unit.
(7) Replace the clear dome cover, after making final camera setup selections and
lens adjustment.