FLASHING LIGHT:
The control unit features an output to control a 24V
the motor.
OPERATION WITH TIMER:
The control unit allows a timer to be connected in place of the open – close push-button.
E.g.: at 08.00 am the timer closes the contact and the control unit commands an opening movement; at 18.00 pm the timer opens the
contact and the control unit commands a closing movement. During the interval 08.00 – 18.00 at the end of the opening phase, the
control unit disables the flashing light, automatic closing and the remote controls.
BUFFER BATTERY:
The control unit has an integral 24V battery charger
capacity of 7 Ah, which will make it possible to carry out some complete maneuvers at reduced speed in emergency mode. The Flashing
Light, when present, will operate only for the first 4 seconds of the movement when mains power is absent.
11.5

PROGRAMMING

SEL key: selects the type of function to be stored; the selection is indicated by flashing of the LED.
By pressing the key several times, it is possible to go to the desired function. The selection remains active for 10 seconds, displayed by
the flashing LED, if elapsed, the control unit returns to its original state.
SET key: programs the information in accordance with the function type preselected with the SEL key.
IMPORTANT: The function of the SET key can also be replaced by the remote control if previously programmed (CODE LED on).
MAIN MENU
The control unit is supplied by the manufacturer with the possibility of selecting a number of important functions.
LED OFF
L1
TX CODE
L2
MOTOR TIME
Factory T. setting
L3
PAUSE TIME
Without aut.close
L4
FORCE OPEN
Maximum
L5
FORCE CLOSE
Maximum
L6
SLOWING OPEN
Maximum
L7
SLOWING CLOSE
Maximum
LEV MENU
1. CODE (Remote control code):
Up to 120 remotes with different codes of either the fixed or rolling code type can be saved on the control unit.
Programming:
The transmission code is programmed as follows: use the SEL key to select flashing LED L1 and transmit the chosen code with the
required remote within 10 seconds; LED L1 will remain steady on to indicate that programming has been completed. After inserting
correctly every radio code, the control unit stays put for 10 sec waiting to receive a new one.
If all 120 codes have been saved, when the programming operation is repeated, all programming LEDs will start to flash, indicating that
no additional codes can be saved.
Remote controls reset:
To delete all the previously saved remotes from the receiver, use SEL to select LED L1, then press SET and hold it pressed for > 5 s. At
the end of this interval the LED will switch off for two seconds to confirm that the procedure has been completed successfully.
First programmed Remote Control rule:
When programming remotes the following rule is applied: if the first remote to be saved is a rolling code type, the receiver will subsequently
accept only rolling code remotes, thus providing enhanced anti-intrusion security; if the first remote to be saved is a fixed code type, the
receiver will subsequently accept both fixed code remotes and rolling code remotes.
CAUTION: Whenever you reset the remotes on the receiver, all the saved remotes will be deleted and also the rule of the first saved
remote control will be reset to default. After each memorized radio control, the control unit waits for a further 10 seconds to store an
additional radio code. Press SELECT key to end the procedure without waiting for 10 seconds.
2. MOTOR TIME (Barrier working time programming):
Programming must be performed with the barrier closed as follows: use the SEL key to select flashing LED L2 and then press the SET
key momentarily; the Motor will start an Opening cycle; when the required slowdown starting point is reached, press the SET key again;
LED L2 will start flashing more slowly and the Motor will decelerate; on reaching the required position press SET to terminate the Opening
cycle. When Opening cycle time programming is completed, the Motor restarts immediately in the Closing cycle: repeat the operations
described above for the Closing cycle.
CAUTION: Slow down phases are controlled by the switch adjustments.
4W max flashing light. Operation of the flashing light depends on the movement of
. The control unit allows the connection of a back-up battery with a maximum
LED ON
No code
Coded entered
Programmed time
With automatic close
Med – min set by speed
Med – min set by speed
Med – min set by slowing
Med – min set by slowing
ON