FRONTAL PANEL DESCRIPTION

GENERAL FUNCTIONS OF THE PUMP :
- 4 LANGUAGES MENU: ITALIAN, ENGLISH, FRENCH, SPANISH
- 2 POSSIBLE TYPES OF FUNCTIONING: Manual, mA Input
- START UP DELAY
- DEFAULT PARAMETER RESTORING
- LEVEL CONTROL
- STOP DOSING ( STAND_BY )
- REAL TIME FLOW RATE %
Default functioning : Manual Flowrate 80%
Other parameters:
 mA Min: 4.0mA
 Flow.Min: 0%
 Dos Min: No
 mA Max: 20.0mA
 Flow.Max: 80%
 Dos Max:Yes
 START UP DELAY: 0sec
DEFAULT SETTINGS RESTORE
PUMP'S CONNECTIONS
Rev 1.0
DEFAULT SETTINGS
Push and quickly release CAL button and then pressing + and – buttons select "Restore
Enter"
Push CAL to confirm the choice. The pump goes back in measure restoring in memory
the default settings and calibrations parameters.
Cod. 00.008.647
1.Display LCD 8 x 2 backlight
2.Green Led: ▪ fix = PUMP ON
▪ blinking = PUMP IN ALARM
3.Red Led: indicates the injections
4.CAL button : ▪ allows to enter in programming
▪ saves the changes
5/6. – and + buttons : ▪ allows to navigate through the
7. ESC/SBY button: ▪ puts the pump in stand_by mode
A – Power cable, 230 V- 50Hz (upon request : 115 ~ )
B – Level probe connector (3 and 4 contacts). OPTIONAL
C –mA input connector (3 (+) and 4 (-) contacts ). OPTIONAL
E - ON_OFF switch. OPTIONAL
menu
▪ Modify the parameters values
▪ allows to exit the menu
7