POSSIBLE FUNCTIONING
During the programming if you do not push any button (+,-, CAL) for more than 60 seconds, the pump will get out of
programming keeping the data stored until that moment.
PROGRAMMING OF MANUAL (CONSTANT) FUNCTIONING AND VISUALIZATION
Rev 1.0
There are 2 possible functioning:
Function Manual: constant dosing (on-off time dosing) with flow rate
programmed as follows in the next paragraph.
Function mA Input: on-off time dosing proportional to the input current.
Push and quickly release CAL button and scroll the menu using + and – buttons
till the display shows "Function Type". Push CAL to enter the submenu and
then by pressing + and – button choice " Function Manual" and confirm
pressing CAL. The display will show "Flowrate" and the % stored in the last
programming. Modify it by pressing + and – button and confirm the choice
pressing CAL. Push ESC button to esc the menu and go back in measure with
the Manual functioning just programmed.
The Flow rate of the pump depends on the % programmed.
The dosing is defined by periods of time of motor-on and motor-off of a total
period of 300 seconds.
For example: Flow Rate 30% means that the pump will dose for 90 seconds
and will stop dosing for the next 210 seconds. This cycle wil be repeated for
ever.
Flow rate 50% means that the pump will dose for 150 seconds and will stop
dosing for the next 150 seconds. This cycle wil be repeated for ever.
Flow rate 80% means that the pump will dose for 240 seconds and will stop
dosing for the next 60 seconds. This cycle wil be repeated for ever.
Flow rate 100% means that the pump will dose without stopping (maximum flow
rate).
In Manual functioning the display shows on the first row "Man." and the % flow
rate programmed.
The second row shows the measure.
Cod. 00.008.647