INSTALLATION
CAUTION
•
In order to avoid a hazard due to inadvertent resetting of the thermal
cutout, this appliance must not be supplied through an external switching
device, such as a timer, or connected to a circuit that is regularly switched
on and off by the utility.
WARNING
•
In order to avoid overheating, do not cover the heater.
•
The heater must not be located immediately below a socket-outlet.
•
The heater must be installed at least 1.8 m above the floor.
•
Means for disconnection having a contact separation in all poles must be
incorporated in the fixed wiring in accordance with the wiring rules.
•
Fixed heaters are to be installed so that switches and other controls
cannot be touched by a person in the bath or shower.
•
This product can be installed in bathrooms but only out of the volumes
according the national wiring rules (For France NF C 15-100).
•
Note: : The above drawing is for reference only. We suggest that you to
contact a professional electrician for assistance.