Push STB button to bring back the pump in the Operating mode and to reset the count of Time Alarm
which re-starts with the dosing (or activity of the plug in DUAL pH/CL REG).
MOD
l/h 1 unit
DUAL-PH_1.5liters 1.5
DUAL-CL 3liters
3
FLOWRATE VISUALIZATION
During the functionnig it is possible to visualize the actual measures or the actual dosing flowrates (actual plug's activity)
simply pushing the ESC button. You can change the visualization pushing again ESC. (See the figure above)
Codice 1075262
pH TIME ALARM EDITING
Push CAL 3 times and scroll the menu by + and - buttons until the
display shows" pH Alarm Time". Push CAL to enter and choose
the alarm time units from 0 to 120 using + and – buttons.
Push CAL to confirm and ESC to go back to measure
Time Alarm=
2000cc :(cc_unit)
25cc
80 unit
40 unit
50cc
Calculation example of the Alarm Time if you wish to inject 2
liters(=2000cc) of maximum product at backpressure of the
pump nameplate.
NOTE: The time alarm has no effect on Manual mode
operation
pag. 27 a 56