Problem
The burner will not
light with a match.
Low Heat.
Dual Fuel Grill
TROUBLESHOOTING
Possible Causes
• Match not reaching burners
(when holding match with hand).
• Empty tank.
• Poor connection between valve
regulator and LP cylinder
coupling.
• Burner inlet blocked.
• The LP-Gas regulator is equipped
with an excess flow device that
allows sufficient gas to the burners
under normal circumstances.
Rapid changes in pressure can
trigger this device and prevent all
but minimal flow of gas to the
burner, causing a low flame and
low heat output. This is typically
caused by the LP-Gas cylinder
valve being turned open when
one or more burner valves
(control knobs) is in the open
position causing a surge of
pressure that activates the
excess flow device.
• Use match holder found in
cabinet door.
• Check fuel level and refill tank if
necessary.
• Turn off grill knobs, close the LP
cylinder value at top of cylinder
and check the connection
between the regulator valve
and cylinder coupling.
Disconnect and reconnect, if
necessary.
• Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the Manual.
• Follow these steps:
1. Close the LP-Gas cylinder
2. Make sure the burner valves
3. Slowly open the LP-Gas
4. Follow the lighting
34
Possible Solutions
valve on the top of the
cylinder.
are in the "OFF" position.
cylinder valve and wait 10
seconds.
instructions.