INSTALLATION
RECOMMENDED INSTALLATION
MAX. 7 bar
OPTION
>=1/4"
FLUID
INLET
AIR EXHAUST DISPOSAL
WARNING
• Optional kit is required for remote exhaust.
• Unscrew the 4 bolts and remove the air cap.
• Connect a hose to the new exhaust port and install the muffler at the
end of the hose. Use a hose with the same diameter as the exhaust port
3/8" NPT. (If the hose is more than 5 feet (1.5 m), consult your dealer or
Samoa Industrial, S.A.).
• Have a moat, a protective housing, etc. at the end of the hose.
AIR CONNECTION
WARNING
To ensure that the air supply is sufficient to meet the demand of the pump,
the diameter of the pipe must be equal to the diameter of the supply port
of the pump. Choose auxiliary air treatment equipment and fittings with
sufficient airflow to exceed the air consumption of the pump. In addition,
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
3/8"
3/8"
INLET
1/4"
OPTION
SUCTION
DRAINING
VALVE
OUTLET
OPTION
1/4"
DISCHARGE
DRAINING
VALVE
peripheral air treatment equipment must be installed as close as possible to
the pump unit.
The use of a coupler to connect the hoses aids future operation and
maintenance tasks.
>=1/4"
REMOTE EXHAUST
3/8" NPT
R. 11/18 855 835
EN
5