DESCRIPTION
Compressed air powered reciprocating piston pump. This high flow capacity pump is compatible with mineral and synthetic oils and suitable for
large installations with long length piping supplying several fluid outlets simultaneously.
This pump can be mounted on the wall, with wall mounting bracket (Part. No. 360132).
WARNINGS
WARNING! Read all instruction manuals, tags, and labels before
!
operating the equipment. This equipment is for professional use only.
• The use of non compatible fluids may cause damage in the pump and
serious personal injury. This equipment is not intended for use with
fluids that fall within the Group 1 fluid as defined that are explosive,
extremely flammable, highly flammable, flammable, very toxic, toxic,
oxidizing or where the vapor pressure if greater than 0,5 bar (7 psi)
above the pressure atmospheric at the maximum allowable
temperature.
• The pump generates high or very high pressures. Do not exceed the
maximum air inlet pressure of 12 bar (170 psi). A direct hit against the
human body may result in an injury.
• This unit may have stored pressure, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of
this unit, all service work should be by qualified personnel only.
• When not in use, be sure to shut off the air supply to avoid accidents.
INSTALLATION
This pump can be mounted directly on the wall, using the
bracket 360132. Firmly fix the bracket to the wall. Put the pump on it
and fix with included screws (fig. 1).

TYPICAL INSTALLATION

Please see figure 2, a typical installation shown with all the recommended accesories for the pump to operate correctly.
NOTE: The compressed air supply must be between 40 and 180 psi (2 - 12 bar), and 80 to 100 psi is ideal.
POS. DESCRIPTION
A
Ball Valve, Low Pressure
B
Filter/Regulator
C
Air hose
D
Quick coupling
E
Connection nipple
F
Pump
G
Pressure Relief Valve
H
Oil hose
I
Ball Valve, Medium Pressure
J
Wall bracket
K
Oil suction hose
L
Ball Valve, Low Pressure
2
853 809 R. 03/18
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
• Do not alter or modify this equipment. Use only Samoa Industrial, S.A.
• All fittings in the system connected to the outlet of the pump should
1000 mm
Part No.
950 319+239 004
241 001
TO OIL
362 100
CONTAINER
251 412
255 312
537 630
609 008
362 303
950 303
539 004
367 003
950 306
genuine components. Any unauthorized tampering with this
equipment, improper use, poor maintenance or removal of
identifications labels may invalidate the guarantee.
be suitable for the maximum possible pressure generated by the
pump/air motor. If the systems cannot be designed to take the
maximum pressure produced by the pump, safety valves or diverter
valves should be fitted.