The 6-channel push-button panel with Easy 1-channel actuator (flush-mounting) is a command device
with 6 channels that can be used on their own or combined, to perform the functions of ON/OFF, dimmer
control, roller shutters control, scene management, priority and timed controls on a KNX BUS.
On the device there is a relay with a change-over contact for managing an On/Off actuator channel that
controls the connected load; the channel allows the implementation of on/off and timed activations,
scenes and forcing. Each device has 3 tilting push-buttons (each of which manages two channels).
The device is powered from the BUS line, and each channel has two LEDs (amber/green) for night-time
localisation and display of the controlled load status.
The push-button panel module is inside the standard flush-mounting boxes, mounted on the Chorus
range supports in the space taken up by three modules.
Functions push-button panel section
Each of the 6 channels of the push-button panel can be configured with the Easy controller to carry out
your choice of one of the following functions:
CYCLIC ON/OFF SWITCHOVER
With this function the electrical loads can be activated or deactivated like, for instance, of the lighting
devices connected to a KNX actuator. The push-button sends the ON and OFF commands alternately.
The status of the controlled actuator is signalled by the LED (amber/green) selected, according to the
indications given in the INDICATOR LIGHT paragraph.
FRONTS MANAGEMENT
With this function the electrical loads can be activated or deactivated like, for instance, of the lighting
devices connected to a KNX actuator.
The channel can be configured for:
• sending the ON command;
• sending the OFF command;
• sending the ON command when the push-button is pressed, and the OFF command when it is released (ON/OFF);
• sending the OFF command when the push-button is pressed, and the ON command when it is released (OFF/ON).
In this mode the device does not allow the automatic control of the signalling LEDs. Their switch-on can be
associated with the status of the actuator contact, by means of a special status channel to be explicitly selected
in the function creating phase.
ON COMMAND WITH TIMER
With this function an electrical load can be activated connected to a KNX actuator, i.e. stair raiser light,
which automatically deactivates after the time set, parameterisable on the actuator. The status of the
controlled actuator is signalled by the LED (amber/green) selected, according to the indications given in
the INDICATOR LIGHT paragraph.