Technical Data - Simon Plug & Drive WALLBOX 2 TOMAS M3T2 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL DATA

Input voltage
Tolerance
Input Frequency
Single-Phase Connector Output voltage
Three-Phase Connector Output voltage
Maximum current of single-phase output (Schuko)
Maximum current of three-phase output (type 2)
Maximum Charge Power
Single and/or Three-Phase connector type:
Single-phase connector type
Operating Temperature:
Equipment: *Simon guarantees the proper functioning of the Mode 3 charging
solution for supply voltage from normal installation in Single/Three-phase. Any
variation in the standardized conditions may alter the proper operation of the
charging solution.
Case details
Material
Rubber case
Finishing
Polyesther paint Black and aluminum
Degree of protection
IP54 / IK09
Anchor
4 points on the wall
Weight
9 kg
Wallbox dimensions:
380x260x150 mm
INSTALLATION
The charging box will be fixed to the wall so that the lower part of the connector
is located at a height of between 0.9 and 1.2 m above the ground, according to
the United Nations Recommendation for Accessibility for the Disabled.
The fixing screws (not included) must have M6 threads, a minimum length of
50mm and with ridged or rounded cylindrical heads no greater than 12.5mm.
Template for wall mounting
POWER CONNECTION AND BUS (optional)
1. Mount (with threaded screws) the cable glands at the lower and/or upper part
of the charging box, as necessary.
2. Open the front cover of the charging solution with Torx TX25H key and tilt cover
with its hinges until in a position perpendicular to the mounting plane of the
charging solution.
400 Vac
10%
50 Hz
230 Vac
400 Vac
16 A
32 A
22 kW (max)
3. Pass the wires through the lower and/or upper gland and located the Power
IEC 62196-2 type 2
and BUS connection block.
UNE 20315-1-2, Schuko
-20º C / 60º C
4. Connect the power cables (single or Three-phase) and BUS (optional) to the
charging box terminal block.
5. Close the front cover of the charging box.
ELECTRONIC CHARGE CONTROL SETTINGS
To access the Electronics, you must lift the plastic visor in the upper front,
unscrewing the access screw.
The load potentiometer switch must be set to 6A-32A.
The position of the configuration switch must ALWAYS be set in the following
manner:
32A SINGLE PHASE SOLUTION CONNECTION SUM-
MARY AND DATA
Connection
Phase 1
Phase 2
Phase 3
Neutral
Ground
5
1
2
3
4
5
6
7
Term
Minimum
Max intensity
section
value (A)
L1
10 mm2
32A
L2
10 mm2
32A
L3
10 mm2
32A
N
10 mm2
32A
T
10 mm2
-
ON
OFF
8
9
10
Cable section
1*10 mm2
1*10 mm2
1*10 mm2
1*10 mm2
1*10 mm2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Plug & drive schukoPlug & drive ze ready

Tabla de contenido