Electrical Connection - CARLO GAVAZZI Guardian 1 Manual Original Del Usuario

Ocultar thumbs Ver también para Guardian 1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Fig. 5 Use the self-adhesive drilling template for correct mounting holes and
cable connection
Pin assignment and colour code:
1 Pink
[PK]
2 White
[WH]
3 Green [GN]
4 Yellow [YE]
5 Red
[RD]
6 Grey
[GY]
7 Blue
[BU]
8 Brown [BN]
Door control system connection:
Power
Signal
Supply
input
12-24 VAC
safety
12-24 VDC
sensor
(inside)
-
+
Guardian 1 inside
!
Note:
Before switching on the unit, remove all objects from the detection area that
do not form part of the usual surroundings of the door. Also make sure that
nobody is within the motion area of the door during the teach-in phase.
The first time the sensor is powered up, all LEDs will form a running light. This
means that there is no valid presence zone stored into the sensor and the out-
puts are set at a safe state.
TEACH-IN
A: Open the door fully.
B: Store presence zone into the sensor by following step 1 and 2.
6

Electrical Connection

Not connected
Test input –
Test input +
Motion Output
Safe Output (presence zone)
Common output
– Supply
+ Supply 12 to 24 VAC/DC
Door control system
Motion
Test
(radar)
output
detector
safety
input
sensor
(inside)
(inside)
-
+
Teaching the Presence Zone:
RIGHT
Cable plug front view
1
2
3
Power
Signal
Motion
Supply
input
(radar)
12-24 VAC
safety
detector
12-24 VDC
sensor
(outside)
(outside)
-
+
Guardian 1 outside
4
5
6
7
8
Test
output
safety
input
sensor
(outside)
-
+

Publicidad

Tabla de contenido
loading

Tabla de contenido