CV
Description
1
Locomotive Address
2
Starting Voltage
3
Acceleration Time
4
Braking Time
5
Maximum Speed
6
Medium Speed
8
Default Settings
17 + 18
Advanced Address
29
Configuration Register
The following CV's must not be changed under any circumstances. 7, 33, 34, 35, 36, 37, 38, 39, 40, 49, 50,60, 61, 62, 63
Meaning
DCC address for the locomotive
Changes the minimum speed
Value * 0.87 gives the time from a standstill to maximum
speed
Value * 0.87 gives the time from maximum speed to a
standstill
Locomotive speed at the highest speed level
Locomotive speed at the middle speed level
Return to the factory default settings
Caution, very complex!
Total value must be calculated.
Total value = Bit 0 value + Bit 1 value + Bit 2 value ...
Bit 0: Direction
Bit 1: 14 speed levels / 28 (128) speed levels
Bit 2: Analog operation possible
Bit 4: Motor operation curve determined by
CV 2, 5, 6 / CV 67 - 94
Bit 5: short / long address
Area
1 - 127
1 - 63
1 - 63
1 - 63
1 - 63
1 - 63
8
128 - 9999
0, 1, 2, 3, 4, 5,
6, 7, 16, 17,
18, 19, 20, 21,
22, 23, 32, 33,
0 / 1
34, 35, 36, 37,
38, 39, 48, 49,
50, 51, 52, 53,
0 / 2
54, 55
0 / 4
0 / 16
0 / 32
Factory
Value
3
3
8
6
63
25
—
255
6
7