New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Fan
WHT
BLK
120 VAC
LINE IN
GRD
MANUAL-ON
SENSOR/CONTROL
BLACK
WHITE
ORANGE
MANUAL - ON
SENSOR / CONTROL
MASTER
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
MULTI-FUNCTION
WALL SWITCHES
LIGHT
NIGHT
LIGHT
MASTER
RED
BLUE
BROWN
SWITCH
BOX
LIGHT
NIGHT
LIGHT
MULTI-FUNCTION
WALL CONTROLS
(purchase separately)
WHT
BLK
RED
14/3
14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
RED
BLU
BLK
WHT
GRD
GROUND
LIGHT RECEPTACLE WIRES
(green or bare)
KNOCKOUT
PLATE
120 VAC
FAN RECEPTACLE
LINE IN
ZB80ML n ZB110ML Installation Guide
3
4
Screw from
Parts Bag
WHT
BLU
LIGHT
RED
NIGHT
LIGHT
SENSOR/
CONTROL
BLK
FAN
BLK
WHT
RECEPTACLES
WIRES
• See OPERATION
section on page 12 for
details.
• MASTER switch
turns fan system
on and shuts it off
for fan cleaning
and maintenance
purposes.
• SENSOR/CONTROL
switch turns motion
control automatic
operation on/off.
• MANUAL-ON switch
directly increases fan
operation to certified
airflow rate.
• MASTER and
SENSOR/CONTROL
switches can be
combined (see page
10).
• Motion sensor can be
wired to control light
(see page 10).
• MASTER switch along
with or separate from
SENSOR/CONTROL
switch may be located
where they are not
easily accessed for
everyday usage;
they may need to be
labeled and located
where they can't be
turned on without
being seen from fan to
comply with local and
national codes.