6. Install the Adapter – Dual Steam Head
Remove the adhesive backing from the steam adapter.
Mount the adapter firmly to the side of the steam generator.
NOTICE: Do not pinch, nail, wedge, or use undue force when
handling the silver crossover cable. Any damage may result in
adapter failure. If the adapter is not installed immediately, protect
the cable ends with tape or other shielding material.
Connect the silver crossover cable to the steam adapter and the
inlet side of the 3-way coupler.
Connect one black straight-through cable to the output side of the
3-way coupler and the first generator.
Connect the other black straight-through cable to the output side
of the 3-way coupler and the second generator.
Connect the temperature sensor wire to the corresponding port
on the steam adapter.
Connect the data cable to the steam adapter and route the cable
to the controller installation location.
1235393-2-A
Controller
25' (7.6 m)
Data Cable
10
Steam
Head
Temperature
Sensor
Steam
Head
Interface