Descargar Imprimir esta página

D+H LAH 65-BSY+ Manual Original página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

Extent of supply
d
g
Starting
Do not run the drive without louvre window,
otherwise the drive could be damaged.
A reference run (zeroing) must be carried out for
the first starting and after exchange of one of the
drives. In this process the drive will determine its
zero point (Closed-position). This single event is
called null balance.
- Connect drive
- Trigger drive in CLOSED-direction
(independent on the position of louvres)
After an overload cutoff has been effected in
running direction „CLOSED", the drive will have a
new zero point. During the reference run, no
obstacle must impair the running of the louvres.
The hand guard in arms's reach is
deactivated during the reference
run (danger of squeezing)!
8/20
LAH 65-BSY+
h
j
c
e
b
a
f
Trouble shooting
Visual inspection:
Only one master-drive allowed.
The master has the last address, corresponding
to the total number of drives.
The adress is sticked on the drive.
Slaves are numbered downwards.
Example: In a group, composed of 3 drives,
there is a master 3, a slave 2 and a slave 1drive.
Attention: only applies by factory set.
As soon as the drives were reprogrammed with
S
CS
the addressing might vary from
factory set addressing.
Wiring:
Is the group wired correctly?
Therefore look connection diagrams.
Reference Run:
It should be zeroed.
Software SCS or the special magnet
MAG 502 is required.
Call D+H Service:
Drives must be configured.
Software SCS is required.
English
a Louvre Drive LAH 65-BSY+
b
Tallow-drop screw
M4 x 12
c
Tallow-drop screw
M2,5 x 5
d Cable clamp
e Connection cable 2,5 m
f Plug - 9 pole
g Mounting plate
h
Sheet metal screw
i
Cable
tie
99.826.56 1.2/04/16
ST4,2 x 16

Publicidad

loading