Hydrajaws Safety Lifeline Instrucciones De Uso página 7

Universal de seguridad verificador de líneas de vida

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

It is recommended that the Hydrajaws test kit is used to perform all proof test described
below.
For swage testing, apply the recommended test load and hold for 3 minutes, checking
for any slipping of the cable from the swage. This will be indicated by the gauge not
holding load and separation of the swage slip indicator away from the end of the swage
termination. If any signs of slippage are detected the swage joint must be rejected and
replaced. For end anchors secured using resin/chemically fixed anchor bolts, the fixing
shall be subjected to an axial pull tester of 10kN. This load shall be held for 3minutes.
End anchor fixings not sustaining the test load must be rejected and replaced for
intermediate anchors using resin/chemically fixed anchor bolt(s), the fixing shall be
subjected to an axial pull test of 5kN. This load shall be held for 3 minutes. Intermediate
anchors not sustaining the test load must be rejected and replaced.
For mechanically fixed end and intermediate anchors secured to structural steelwork
the fixing bolts shall be subjected to a torque check to the recommended values. If
tightening torque value is not achieved the fixing bolts should be replaced.
For end anchors secured using expansion anchor bolts the fixing shall be subjected to
an axial pull test to 10kN. This load shall be held for 3 minutes. For intermediate anchors
secured using expansion anchor bolts the fixing shall be subjected to an axial pull test
to 5kN. This load shall be held for 3 minutes.
All single point anchors, push lock safety ring etc should be subjected to an axial pull
test of 6kN this load shall be held for 3 minutes.
ASSEMBLY INSTRUCTIONS OF 600mm LOAD SPREADING BRIDGE TO MODEL 2000/C
1.
Hold the bridge horizontal with the top plate visible (2000 tester mounting plate)
2.
Slide the legs through the block with the round foot toward the ground.
3.
Align the holes at the desired height and place the pin through until the ball bearing
releases.
4.
To mount the Model 2000 tester to the bridge remove the existing bridge and make
sure the M12 locking adaptor is located in the operating jaw.
5.
Turn the bridge upside down with the round feet in the air.
6. By using the same screws you removed from the other bridge line up the holes and
use the 3mm ball driver.
7.
Use the M12 coupler supplied with the bridge and screw this fully into the locking
adaptor. The other end will then except the M12 Ringbolt Adaptor Clevis (figure 34).
GB