Supply conditions
Mains connection
Power system
TT, TN
(with an earthed neutral)
Delta system
(outer conductor−earthed)
IT system
Voltage deviations
Voltage dips
Control connections
Supply
Digital inputs
Digital output
Ambient conditions
Climatic
Transport
Storage
Operation
Site altitude
Permissible pollution
Mechanical
Vibration resistance
Transport
Operation
Vibrational severity
EMC
Interference emission
Cable−guided
Radiation
Noise immunity
Operation on public supply
systems
Lenze ¯ MDKSEMA ¯ 5.0
Operation permitted without restrictions
Operation not permissible.
Operation not permissible.
EN 61800−3
Short−time mains voltage dips (cf. IEC 61000−2−1) may cause disconnection.
24 V DC (19.2 ... 28.8 V) by safely separated power supply unit (SELV/PELV)
IEC 61131−2, type 1
24 V DC, input resistance 5.6 kW
IEC 61131−2, type 1
24 V DC, max. 50 mA
IEC/EN 60721−3−2
2K3 (−30 °C ... +70 °C)
IEC/EN 60721−3−1
1K3 (−30 °C ... +60 °C)
1K3 (−30 °C ... +40 °C)
IEC/EN 60721−3−3
3K3 (−10 °C ... +40 °C)
3K3 (−30 °C ... −10 °C)
< 1000 m amsl
> 1000 m amsl < 4000m
amsl
EN 61800−5−1
2
IEC/EN 60721−3−2
2M2
IEC/EN 60721−3−3
3M4
EN 60034−14
A
In TN and TT systems
EN 61800−3
Category C2
EN 61800−3
Category C2
EN 61800−3
Requirements for industrial environments are complied with
EN 61000−3−2
The devices are designed for the use in industrial environments. If they are used
on public systems, measures to reduce the expected emission of radio
EN 61000−3−12
interferences are to be implemented. The machine/system manufacturer is
responsible for compliance with the requirements for the machine/system!
Technical data
General data and operating conditions
< 3 months
> 3 months
Variant for deep−freeze applications
If combined with a gearbox:
The gearbox must also be suitable for the
temperature range.
Without power reduction
With power reduction 5 %/1000 m
3
EN
31