SATA 03022 Manual Del Uso página 31

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 124
2. When the input terminal is open circuited, "overload" will appear.
3. Before online resistance measurement, switch off the power of the measured circuit
and fully discharge all capacitors
h) Continuity test
1. Insert the black probe into the "COM" jack and the red probe into the "
2. Set the function switch to "
button until an "
3. Connect the probes to the two ends of the circuit to be measured.
4. The built-in beeper sounds when the resistance is less than about 20 Ω .
Note
Before the test, switch off the power of the measured circuit and fully discharge all
capacitors.
i) Diode test
1. Insert the black probe into the "COM" jack and the red probe into the "
(Note: The polarity of the red probe is "+".)
2. Set the function switch to "
button until an "
3. Connect the red probe to the positive pole of the diode to be measured and the black
probe to the negative pole.
4. Read the approximation of the forward voltage drop of the measured diode indicated
on the screen.
03022
". And then press and hold the "function selection"
" symbol appears on the screen.
". And then press and hold the "function selection"
" symbol appears on the screen.
EN
DE
- 26 -
RU
KO
PT
JA
ES
" jack.
" jack.

Publicidad

Tabla de contenido
loading

Tabla de contenido