Troubleshooting
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining
any residual water.
IMPORTANT! Turn off the power and water supply to the valve before performing any maintenance.
It is recommended that any valve maintenance should be performed by a Kohler Co. Authorized Service
Representative.
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
1-800-4KOHLER.
Troubleshooting Table
Symptoms
1.
Control panel is not lit.
2.
The interface power
indicator is lit, but the
system will not turn on.
3.
The interface functions
normally but no water
flows from the
components.
4. Maximum blend
temperature too hot or
too cold.
Kohler Co.
Probable Cause
A. Valve is not plugged into the
outlet.
B. Interface cable connections may
be loose or disconnected.
C. Circuit breaker has been
tripped.
D. The valve memory may require
resetting.
E. A "straight-through" cable or
coupler was used to connect the
interface to the valve.
F.
If none of the recommended
actions for the above issues
correct the symptom, the valve
or interface requires servicing.
A. Interface cable connections may
be loose.
B. If the above recommended
action does not correct the
symptom, the interface or valve
requires servicing.
A. Valve outlets may be blocked.
B. Fittings/Spray faces may be
blocked.
C. Hot and cold water supplies are
not turned on.
D. The valve memory may require
resetting.
E. System error.
F.
If none of the recommended
actions for the above issues
correct the symptom, the valve
requires servicing.
A. Incorrect maximum temperature
setting.
9
Recommended Action
A. Plug the valve into an outlet.
B. Check all interface cable
connections, connect if needed.
C. Reset the circuit breaker.
D. Disconnect and reconnect the valve
power cord from the electrical
outlet.
E. Connect the interface to the valve
using a "cross-over" cable or
coupler.
F.
Contact your Kohler Co.
Authorized Service Representative.
A. Check all interface cable
connections, connect if needed.
B. Contact your Kohler Co.
Authorized Service Representative.
A. Check the valve outlets for
blockage or debris. Clean the outlet
screens. Refer to the "Clean the
Outlet Screens" section in the Valve
Homeowners Guide.
B. Clean the spray faces and any
screens in your fittings.
C. Turn on the water supply to the
valve.
D. Disconnect and reconnect the valve
power cord from the electrical
outlet.
E. Check the user interface for an
error code. Refer to the "Error Code
Diagnosis" section in the Digital
Interface Homeowners or User
Guide.
F.
Contact your Kohler Co.
Authorized Service Representative.
A. Refer to the "Set the Maximum
Temperature" section in the Digital
Interface User Guide.
1143086-2-D