5. INSTALLATION INSTRUCTIONS 5. INSTRUCCIONES DE INSTALACIÓN...
Página 2
WARNINGS ADVERTENCIAS Ø The diameter of the extraction tube must be at least of 300mm, or 11,8 inches , for all the models. El diámetro del tubo de extracción debe ser como mínimo de 300mm para todos los modelos. All the extractor hood’s measurements in this chapter 5, Installataion instrucctions, are the minimum recommended.
5.1 OVEN ASSEMBLY MONTAJE DEL HORNO This steps are not necessary when assembling a Make sure that the bolt and the hole on the HJA-20 oven. panel door are centered. DO NOT screw the nuts if the bolt is not well Estos pasos no son necesarios al montar un horno centered, it may cause the door panel to break.
Página 4
5.1 OVEN ASSEMBLY MONTAJE DEL HORNO The handle regulator has to be put in a rabbet in the ashe’s gate plate. Once the handle has been put check that it was correctly placed. El tirador regulador se coloca en una ranura dentro del plato compuerta de las cenizas.
Página 5
5.1 OVEN ASSEMBLY MONTAJE DEL HORNO INSTALLATION INSTRUCTIONS / INSTRUCCIONES DE INSTALACIÓN...
Página 6
5.2 WITH EXTRACTOR HOOD CON CAMPANA EXTRACTORA OVEN ISNTALLED UNDER EXTRACTOR HOOD HORNO INSTALADO BAJO CAMPANA EXTRACTORA It is recommended a weekly cleaning of Firebreak, avoids that flames and the componentes, specially the filters. sparks go into de ventilation ducts. Se recomienda la limpieza semanal de Cortafuegos, evita que las llamas o sus componentes, especialmente los...
Página 7
5.2 WITH EXTRACTOR HOOD CON CAMPANA EXTRACTORA RECOMMENDED SUCTION RATE: 1471 CFM HJA-20 CAUDAL DE ASPIRACIÓN RECOMENDADO: 2500 M [35,43] [35,43] [13,39] [32,68] 1200 [20,79] [47,24] [31,22] The parts of the oven which are in contact with the furniture must be sealed with silicone. Se deben sellar con silicona las partes del horno que encuentran en contacto con el mueble.
Página 8
5.2 WITH EXTRACTOR HOOD CON CAMPANA EXTRACTORA RECOMMENDED SUCTION RATE: 1648 CFM HJA-25 CAUDAL DE ASPIRACIÓN RECOMENDADO: 2800 M 1100 1300 [43,31] [51,18] [22,64] 1200 [29,92] [26,57] [47,24] 1042 [41,02] MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [11,8 in] RECOMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS RECOMMENDED WORKING SPACE FOR CHEF THIS DISTANCE MAY BE MODIFIED BY THE SMOKE OUTLET SET CONFIGURATION...
Página 9
5.2 WITH EXTRACTOR HOOD CON CAMPANA EXTRACTORA RECOMMENDED SUCTION RATE: 2060 CFM HJA-45 CAUDAL DE ASPIRACIÓN RECOMENDADO: 3500 M 1500 1300 [59,06] [51,18] [22,64] 1050 1200 [41,34] [26,57] [47,24] 1102 [43,39] MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [11,8 in] RECOMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS...
Página 10
5.2 WITH EXTRACTOR HOOD CON CAMPANA EXTRACTORA RECOMMENDED SUCTION RATE: 2237 CFM HJA-50 CAUDAL DE ASPIRACIÓN RECOMENDADO: 3800 M 1500 1550 [59,06] [61,02] [22,64] 1050 1200 [41,34] [36,61] [47,24] 1357 [53,43] MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [11,8 in] RECOMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS RECOMMENDED WORKING SPACE FOR CHEF...
Página 11
INSTALLATION UNDER KITCHEN’S MAIN EXTRACTOR HOOD AND ADDITIONAL INDEPENDENT EXIT FOR THE JOSPER OVEN INSTALACIÓN DEBAJO DE CAMPANA EXTRACTORA PRINCIPAL DE LA COCINA Y SALIDA INDEPENDIENTE ADI- CIONAL PARA EL HORNO JOSPER Extractor hood’s conduct It is recommend a Josper oven specific...
Página 12
1200 [20,79] [47,24] 5.3 WITH INDEPENDENT EXIT CON SALIDA INDEPENDIENTE [31,22] RECOMMENDED SUCTION RATE: 1471 CFM HJA-20 CAUDAL DE ASPIRACIÓN RECOMENDADO: 2500 M [35,43] [35,43] [13,39] [32,68] 1200 [20,79] [47,24] [31,22] The parts of the oven which are in contact with the furniture must be sealed with silicone. Se deben sellar con silicona las partes del horno que encuentran en contacto con el mueble.
Página 13
5.3 WITH INDEPENDENT EXIT CON SALIDA INDEPENDIENTE 1200 [29,92] [26,57] [47,24] 1042 [41,02] RECOMMENDED SUCTION RATE: 1648 CFM HJA-25 CAUDAL DE ASPIRACIÓN RECOMENDADO: 2800 M 1100 1300 [51,18] [43,31] [22,64] 1200 [29,92] [26,57] [47,24] 1042 [41,02] MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [11,8 in] RECOMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS RECOMMENDED WORKING SPACE FOR CHEF...
Página 14
5.3 WITH INDEPENDENT EXIT CON SALIDA INDEPENDIENTE 1050 1200 [41,34] [26,57] [47,24] RECOMMENDED SUCTION RATE: 2060 CFM 1102 [43,39] HJA-45 CAUDAL DE ASPIRACIÓN RECOMENDADO: 3500 M 1500 1300 [59,06] [51,18] [22,64] 1050 1200 [41,34] [26,57] [47,24] 1102 [43,39] MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [11,8 in] RECOMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS...
Página 15
5.3 WITH INDEPENDENT EXIT CON SALIDA INDEPENDIENTE 1050 1200 [41,34] RECOMMENDED SUCTION RATE: 2237 CFM [36,61] [47,24] 1357 HJA-50 CAUDAL DE ASPIRACIÓN RECOMENDADO: 3800 M [53,43] 1500 1550 [59,06] [61,02] 1050 1200 [41,34] [36,61] [47,24] 1357 [53,43] MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [11,8 in] RECOMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS RECOMMENDED WORKING SPACE FOR CHEF...