S20
GB
ELECTRICAL POWER CONNECTIONS
Motors:
-
-
+
T1
MOTOR RUN TIME
DWELL TIME
1s - 22s
1s - 180s
DIP-SWITCH 12:
ON: Motor run time max 90s
OFF: Motor run time max 18s
12
Limit switch:
Electric valve power supply:
In case of power failure, electronic programmer
malfunctionning, or a burnt fuse, should an electric
valve be installed, the bollard lowers automatically.
External flashing light:
Signal led lights:
Acoustic signal "Beeper" during movement:
PCB power supply:
Electronic programmer power supply
ELECTRONIC PROGRAMMER UP TO 2 BOLLARDSWITH OR WITHOUT LIMIT SWITCHES
+
T2
There is no need to bridge the limit switch inputs of the
posts which are not present in the installation.
A
B
A
19 20
16 17
18
M1
M2
22
23
24
25
DIP-SWITCH 4 and 10:
51
52
53
ON: Pre-flashing
OFF: No pre-flashing
4
ON: Flashing light out of service
OFF: Light flashes on Dwell Time.
10
230V 100W MAX
51
52
53
SIGNAL LED LIGHTS OUTPUT
230V 100W MAX
51
52
53
ACOUSTIC SIGNAL DEVICE 230V 100W MAX
22
23
24
25
10
B
21
11 12 13 14 15
11 12 13 14 15
on Dwell Time. Automatic mode
Automatic mode
meccanica