Meccanica Fadini Elpro S20 Folleto De Instrucciones página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
S20
GB
63 64 65 66 60 61
Fuse 1A
Red
Yellow
Green
RADIO
PLUG-IN
(Optional: Plug-in PCB
CARD
CONNECTOR
for traffic light to suit
230 V lamp)
code 7282L
"STRIP" jumper
LIMIT SWITCH DIAGNOSTIC:
Talos range of bollards, Talos M30, Strabuc 930 Opinat:
With the "STRIP" jumper inserted (as in the picture), Elpro S20 checks cyclicly every
10 minutes that the closing limit switches (post raised) are in the correct position;
should any of them fail to be such, only the motor of the post not in position is
operated until this is fully up as required.
Note well: Whenever Elpro S20 is re-powered, wait 10 seconds for the logic to become fully operating again.
The electronic control panel Elpro S20, new generation, is designed to operate the Talos range, Talos M30, Strabuc 930 Opinat, Coral and Vigilo; power supply is 230V
single-phase.
Elpro S20 is capable of monitoring damages or malfunctioning with the system (ISC)
I.S.C.= Integrity and Supervision Circuit, is a special function of Elpro S20 which can self control the electronic PCB and detect any damages occurring with any components
or accessories. In this case, provided that the post is fitted with a release electric valve, lowering is allowed automatically.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
2
- Use 1.5mm
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50m.
2
- Use 1mm
section wires for limit switches, photocells, push-buttons/key- switch and accessories.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
ELECTRONIC PROGRAMMER UP TO 2 BOLLARDSWITH OR WITHOUT LIMIT SWITCHES
PLUG-IN CONNECTOR FOR 3-
LAMP TRAFFIC LIGHTS MAX
100W EACH LAMP
-
-
+
T1
T2
MOTOR RUN TIME
DWELL TIME
1s - 22s
1s - 180s
DIP-SWITCH
ON
OFF
1
2 3
4 5 6 7 8
91011 12
Elpro S20
L1
L2
L3
L5
L4
57 58
1
2
3
4
5
6
+
-
55 56
Secondary
24V DC output
transformer
+
L6
L7
L8
L9
L10
7
8
11 12 13 14 15
9
10
8
20VA 50/60Hz
fuse
F4= 2A
TRANSFORMER
L11
A
A
B
19 20
21
16 17
18
M1
M2
1
2
Coral and Vigilo range of posts:
For the posts that are fitted only with the
opening limit switch, position the "STRIP"
jumper as in the picture to achieve a correct
performance of the system.
meccanica
FADINI
Primary
fuse transformer
F3= 630mA
51
52
53
Electric valve fuse,
Acoustic device, Flashing
light and Led F5=2A
Motor fuse M2
F2= 5A
Motor fuse M1
F1= 5A
Anti-disturbance filter
B
22
23
24 25

Publicidad

Tabla de contenido
loading

Tabla de contenido