Dip-Switches - Meccanica Fadini Elpro S20 Folleto De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
S20
GB
IN CASE OF FAILURE OF THE PANEL:
- Check the electronic PCB voltage supply is 230V 10%
- Check the electric motor power supply is 230 V 10%
- For longer distances increase wire section
- Check power supply 230V single-phase
- Check fuses
- Check all NC contacts
- Check that no voltage drop has occurred from the control board to the electric motor
- In case the electric valve is fitted, check integrity with all fuses
LED STATUS INDICATION
L1= Pedestrian opening, normally OFF, alight when a pedestrian open pulse is given
L2= Photocells or loop, normally ALIGHT, if obstructed light goes off
L3= Open, normally OFF, alight when an open pulse is given
L4= Close, normally OFF, alight when a close pulse is given
L5= Stop, normally ON, it goes off when a stop pulse is given
L6= Radio, normally OFF, alight when a Radio pulse is given
L7= Normally ON, mains voltage and fuse integrity F1, F2, F3, F4
L8= Limit switch open M1, normally ON, it goes off when the post is in down position
L9= Limit switch close M1, normally ON, it goes off when the post is in up position
L10= Limit switch open M2, normally ON, it goes off when the post is in down position
L11= Limit switch close M2, normally ON, it goes off when the post is in up position
LOW VOLTAGE ELECTRICAL CONNECTIONS
Photocells or Loop Detectors:
1 2
PHOTOCELLS OR
LOOP DETECTORS
Key switch:
Radio Contact:
- Open/Close (standard mode)
- It reverses at any pulse
- Step by step
24V 3W Movement Indication Light:
Light ON= Post in down position, free passage
Light OFF= Post in up position, closed passage
Flashing 0,5s (fast)= rising post
Flashing 1s (normally)= lowering post
With external clock: 2 short flashes followed by a longer pause
ELECTRONIC PROGRAMMER UP TO 2 BOLLARDSWITH OR WITHOUT LIMIT SWITCHES
DIP-SWITCH 1:
9 10
1
DIP-SWITCH 11:
24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
11
4
3
5
6
NO
NO
NC
3
7
3

DIP-SWITCHES

1= ON Photocells or loop stop while opening
2= ON Radio no reversing while opening
3= ON Automatic closing
4= ON Pre flashing activated
5= ON Radio step by step stop in between
6= ON Pedestrian opening Motor M1only one post operating
7= ON Deadman control
8= Traffic lights (see functions)
9= Traffic lights (see functions)
10= ON No lamp on during dwell time
11= ON Close on dwell time after passage through photocells or over the loop
12= ON Max working time 90s. OFF= 18s
ON: Photocells or loop stop while opening,
reverse on closing once obstacle is removed
OFF: Photocells or loop do not stop while
opening, reverse on closing in case
of an obstacle
ON: During dwell time, Automatic mode
(Dip-Switch 3=ON) after engaging the photocells
or loop, it closes 5s later
OFF: It does not close after engaging
the photocells or loop
DIP-SWITCH 2:
ON: It does not reverse on opening
OFF: It reverses at any pulse
2
24V DC Output:
8
Output for 24V D.C. applications
9
2
1
1
2 3
4 5 6 7 8
F A
D
I N
I
DIP-SWITCH 5:
ON: Step by step with stop in between
OFF: Standard operation
5
+
55 56
200mA for accessories
meccanica
FADINI
ELPR O
S40
1 2
ON
OFF
9 10 11 12
F A
D I
N I
-

Publicidad

Tabla de contenido
loading