Information for use
sera flore CO
pressure reducer with integrated fine needle valve, bottle
2
and working pressure gauge (high and low pressure gauge)
Please read these instructions carefully and keep for
future use.
The sera flore CO
pressure reducer is a precision device
2
equipped with a high precision fine needle valve for do-
sing small amounts as required for aquarium purposes.
State-of-the-art technology that has proven well for de-
cades allows to carry out all assembly and adjustment
measures of the sera flore CO
pressure reducer with -
2
out any tools.
S FETY PREC UTION
Liquid carbon dioxide is under high pressure. Wear pro-
tective goggles for your own safety when carrying out
assembly work.
Usage and application range
For connection to all CO
bottles with external valve and
2
the sera CO
disposable bottle with a special adapter.
2
The seramic pH Controller, the sera CO
System, calcium
2
reactors and other systems depending on CO
working pressure of 2.5 bar (36.25 psi.), can be connec-
ted to the low pressure outlet of the sera flore CO
pressure reducer.
Kit includes
sera flore CO
pressure reducer with two gauges for
2
CO
bottle pressure and working pressure, high preci-
2
sion fine needle valve and pressure relief valve
Parts (fig. 1)
(Device is completely assembled)
1.1 Bottle pressure gauge (high pressure gauge)
Display: 0 – 250 bar (0 – 3625 psi.)
1.2 Working pressure gauge (low pressure gauge)
Display: 0 – 6 bar (0 – 87 psi.)
1.3 Pressure relief valve,
triggering pressure > 3.3 bar (47.86 psi.)
1.4 Steel cylinder casing
1.5 Knurled screw for working pressure adjustment
1.6 Fine needle valve adjustment screw for adjusting
the CO
amount
2
1.7 Union nut for connection to CO
bottle
2
1.8 Seal ring
1.9 CO
hose connector with union nut
2
ssembly and start of operation
1. Basic adjustment
Set the knurled screw (1.5) for the working pressure
to the minimum position, as far as it will go to the
left. Now check whether the adjustment screw (1.6)
of the built-in fine needle valve is closed.
Gently screw in the adjustment screw as far as it will
go. Check whether the seal ring (1.8) of the pressure
reducer is in place correctly and that it is not dam-
aged.
2. Connection to the CO
pressure gas bottle (fig. 2)
2
Hold the CO
pressure gas bottle vertically (valve on
2
top!), remove the protection cap and firmly screw on
the pressure reducer by hand without using any
tools (2.1). The pressure relief valve should then be di-
rected upwards (1.3).
Place the CO
pressure gas bottle in a way that it can-
2
not fall over or drop. The distance from the aquarium
should not be more than 1.5 m (1.6 yd.), as unneces-
sary CO
loss may occur in very long hoses due to dif-
2
fusion.
3. Connect the CO
pressure hose (fig. 3.1 – 3.5)
2
Screw the union nut (1.9) off the CO
Push the union nut onto the CO
CO
hose onto the CO
connector (3.3) and fasten the
2
2
CO
hose with the union nut (3.4). You should install a
2
non-return valve between the CO
pressure reducer (3.5) approx. 30 cm (11.8 in.) before
the sera flore CO
pressure reducer. Connect the
2
, up to a
other end of the CO
hose to your CO
2
2
ing to the instructions of the manufacturer.
2
4. Open the CO
pressure gas bottle
2
Then open the main valve on the CO
bottle (2.2). The high pressure gauge (1.1) will then
dis play the pressure inside the bottle.
5. djust the working pressure
Now adjust the pressure at the low pressure gauge
to 0.8 – 1.0 bar (11.6 – 14.5 psi.), using the knurled
screw (1.5) for working pressure adjustment.
Do not exceed the level recommended by the manu-
facturer for the installed CO
system when operating
2
the CO
setup. Immediately reduce the working pres-
2
sure in this case.
The selected working pressure automatically remains
constant until the CO
bottle is empty.
2
TTENTION!
Please do not exceed a working pressure of 2 bar
(29 psi.) when using the seramic pH Controller.
The working pressure for the sera flore CO
diffuser is approx. 1.5 bar (21.75 psi.).
Please follow the according manufacturer instruc-
tions when using other CO
components.
2
6. Supply CO
to the system
2
Now slowly open the fine needle valve (1.6) until you
see the first bubbles ascend in the bubble counter.
Then adjust the desired number of bubbles. It may
now take several minutes until the system stabilizes.
Correct the adjustment only in small steps.
7. Disassembly
Close the bottle valve (2.2) and the fine needle valve
(1.6). Unscrew the union nut (1.9) and pull the CO
hose off the CO
connector. Then release the pressure
2
remaining within the pressure reducer by opening
the fine needle valve (1.6). You can screw off the pres-
sure reducer when both gauges display zero pres-
sure. Loosen the connecting union nut (1.7) and pull
the pressure reducer off to do so.
8
Operation
In a few cases, it may be necessary to readjust the wor-
king pressure after operation has started. Correcting
the working pressure may only take place after the fine
needle valve (1.6) has been closed again. Pull the CO
hose off the pressure reducer (3.3) for adjustment and
alter the working pressure with the knurled screw (1.5)
slowly and in small steps. Open the fine needle valve (1.6)
for 1 second every time you moved the knurled screw
(1.5). This is important when lowering the working pres-
sure as to make sure the newly adjusted pressure is dis-
played. Connect the CO
" ssembly and start of operation", item 3). Then slowly
and stepwise open the fine needle valve (1.6) until the
desired number of bubbles is reached. Remember to
consider the delayed change of the bubble number.
connector (3.1).
Cleaning
2
hose (3.2). Push the
The pressure reducer should be cleaned only with a dry
2
cloth.
void water getting into the pressure reducer as to
system and the
avoid inside corrosion.
2
system accord -
Maintenance
2
The unit can be maintained or repaired only by the
manufacturer. Only the seal ring of the high precision
fine needle valve and the seal ring at the CO
pressure gas
can be changed. The seal ring is conical and is inserted
2

Troubleshooting

Problem
No CO
gets into the
2
aquarium
CO
consumption too high
2
pressure
2
Hissing noises
Technical Data
High pressure gauge
Low pressure gauge
Safety valve triggering pressure > 3.3 bar
2
djustable working pressure
Permissible room temperature
Dimensions approx.
with the narrow side towards the CO
ll other components must not be screwed off nor
changed in their position, as the special sealing com-
pound will otherwise be damaged, leading to the unit
becoming leaky.
2
S FETY PREC UTIONS
• Liquid carbon dioxide is under high pressure. Wear
protective goggles for your own safety when carry-
ing out assembly work.
hose again (see chapter
• The pressure reducer is pre-adjusted to a maximum
2
pressure of 2.5 bar (36.25 psi.). Manipulation of the ad-
justment screw may cause high pressures on the low
pressure side.
• The safety valve opens at approx. 3.3 bar (47.86 psi.)
and must not be manipulated.
fter a while, the bubble number may considerably
deviate from the adjusted bubble number under un-
usual circumstances (strong temperature variations)
or due to dirt inside the bottle valve, the pressure re-
ducer or another part of the CO
check the bubble number daily, as to avoid danger
for the aquarium inhabitants. Check that the seal ring
(1.8) is properly placed and in unobjectionable condi-
tion every time before screwing the sera flore CO
pressure reducer onto a CO
assembly instruction. Immediately replace the seal
bottle (1.8)
ring if in doubt. The narrow end of the conical seal
2
ring is directed towards the bottle.
Possible cause
Possible solution
Non-return valve installed in
Install non-return valve in
the wrong direction
opposite direction
CO
bottle empty
Change bottle or have it refilled
2
CO
hose bent
Check hose laying
2
Working pressure too low,
Slowly increase working pressure, do not
bottle valve closed
exceed limit provided by the manufacturer
when doing so; open bottle valve
Leakage at the pressure reducer
Check seal rings
and replace them if applicable
Wrong or too long CO
hose
Replace or shorten hose
2
Pressure reducer is not firmly
Check for tight fit on the thread
fastened on the CO
bottle valve
and correct it if applicable
2
Too strong aeration
Reduce aeration
Leakage at the pressure
Check seal rings
reducer
and replace them if applicable
Spare parts
Seal ring for CO
0 – 250 bar
Seal ring for high precision fine needle valve
(0 – 3625 psi.)
djustment screw for high precision fine needle valve
0 – 6 bar
Union nut for CO
(0 – 87 psi.)
(47.86 psi.)
0 – 2.5 bar
(0 – 36.25 psi.)
10 – 40°C
(50 – 104°F)
125 x 105 x 97 mm
(4.9 x 4.1 x 3.8 in.)
9
bottle.
2
system. Therefore
2
2
bottle, and follow the
2
bottle
2
hose connector