■ How to reset when operation stops due to "Dry Firing"
* If Dry Firing occurs, the "HEAT" light of the operational area will blink.
In this case, please perform the reset procedure as follows:
1. Confirm that the water supply at the stop valves
is turned on.
2. Press the "TANK FILL" switch.
* The light will stop blinking, and the tank
will be supplied with water.
3. Confirm that the tank is full via spout steady flow
of water.
4. Press the "HEAT" switch, turning it "ON."
* The heating operation will begin, once heating is
complete please confirm that hot water comes
out of the spout.
If hot water does not come out of the spout, the overheating protection device is engaged and may need to be reset
1. Press "HEAT" switch to "OFF".
2. Unplug the power plug.
3. Remove the front cover / bottom cover.
4. Press the reset button.
5. Install the front cover / bottom cover.
6. Insert power plug into outlet.
7. Wait about 10 seconds and press the
"HEAT" switch to "ON".
* Once the heating completes, please
confirm that hot water comes out.
WARNING
To prevent electric shock, unplug the power plug before removing the front cover.
HOW TO USE
Light blinks
Front cover
Bottom cover
Mounting screws
(2 places)
Open the cover and press the
reset button
23
"TANK FILL" switch
"HEAT" switch
Remove
Reset button

Publicidad