Installation - Everbilt SLT370 Guía De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

CAUTION: Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of
extended use.
1
Inserting the float rod
Insert the plain end of the float rod (1) up through the eye of the
rod guide (2)
3
Sliding the second rod stop to the
rod
Slide the second rod stop (1) on the rod (2) after passing
through the eye of the switch (3).
2
Sliding the rod through the pump
switch
Slide one rod stop (1) on the float rod (2) before passing the rod
through the eye of the pump switch (3).
4
Positioning the two rod stops
Position the second rod stop (1) flush with the top of the rod (2).
For 1001093963, position lower rod stop (3) to within 7 in. (17.8
cm) of switch lever arm (4). With lower rod stop (3) in this
position, pump will automatically cycle at approximately 3 in.
(7.6 cm) off and 10 in. (25.4 cm) on.
For 1001758307, position lower rod stop (3) to within 8 in. (20
cm) of switch lever arm (4). With lower rod stop (3) in this
position, pump will automatically cycle at approximately 2-1/2
in.(6 cm) off and 10-12 in. (25-30 cm) on.
For faster cycling, move the lower rod stop (3) closer to the
switch lever arm (4).
6

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Scn250-lq10017583071001093963

Tabla de contenido