Troubleshooting

Problem
The pump does not start or run.
The pump operates but pumps little or no
water.
The pump starts and stops too often.
The pump will not shut off.
Possible Cause
1. The fuse is blown.
2. The breaker is tripped.
3. The plug is disconnected.
4. The plug is corroded.
5. There is thermal overload.
6. The float switch failed.
7. The motor failed.
1. The screen is blocked.
2. Debris is caught in the impeller or
discharge.
3. The impeller is loose on the shaft or the
impeller is broken.
1. There is a backflow of water from the
piping or the check valve is leaking.
2. The switch is tangled.
3. The float switch failed.
1. The switch is tangled.
2. The float switch is faulty.
3. The float is obstructed.
9
Corrective Action
1. Replace the fuse.
2. Reset the breaker.
3. Secure the plug.
4. Clean the plug prongs.
5. Unplug for 30 minutes and then plug
in again.
6. Replace the float switch.
7. Replace the pump.
1. Clean the screen.
2. Remove the debris.
3. Reassemble the impeller or replace
the impeller.
1. Install a check valve or replace the
check valve.
2. Reposition the pump and make sure
the switch moves freely.
3. Replace the switch.
1. Reposition the pump and make sure
the switch moves freely.
2. Replace the switch.
3. Remove the obstruction.
Please contact 1-844-241-5521 for further assistance.