Fault finding

Fault
The appliance not
working
Water collects
in the bottom
of the cabinet.
Vibration or
bothersome
noise.
Compressor runs
continuously.
P1 is shown on the
display.
P2 is shown on
the display.
Possible cause
The appliance is switched off.
Power failure; the fuse is
blown; the appliance is not
plugged in correctly.
The defrost water pipe is
blocked.
The appliance is not
level.
The
appliance
is
against
other
kitchen
elements.
Containers or bottles inside
the
cabinet
are
against one another.
High room temperature.
The upper sensor is
disconnect- ed or short-
circuited.
The lower sensor is
disconnected or short-circuited.
Remedy
Press the on/off switch.
Check that power is
connected. Reset the fuse.
Clean the defrost water
channel and the drain hole on
the rear wall of the cabinet.
Level the appliance using a
spirit level.
resting
Move the appliance away
from the kitchen elements or
appli-ances it is in contact
with.
rattling
Move containers and/or bottles
apart.
Ensure adequate ventilation.
Call for service. The
temperature within the entire
cabinet is main- tained at the
higher of the two setpoints
until the fault has been
corrected.
Call for service. The
temperature within the entire
cabinet is main- tained at the
higher of the two setpoints
until the fault has been
corrected.