Technical Data - DeguDent Biosint Extra Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1.1 Information for the processing of mixing liquids for dental investment
materials
Following contact with skin:
Following eye contact:
Mixing liquids are alkaline
The Safety Data Sheet includes further details

2 Technical data

Mixing ratio
Total expansion
Mixing time under vacuum
Processing time span
Compression strength
The total expansion, i e the sum of setting expansion and thermal expansion can
be changed by diluting the Biosol E mixing liquid
Mixing liquid
consisting of:
Water
4 parts
2 parts
1 parts
0 parts
12
GA_Biosint Extra_50571813g_1014.indd 12
Upon skin contact, wash with plenty of water
Rinse thoroughly with plenty of water keeping eyelid open
In case of persistent discomfort: Consult an ophthalmologist
Biosol E
0 parts
2 parts
3 parts
4 parts
100 g powder : 15 ml liquid
0 95 % – 1 65 %
60 sec
3 – 5 min
according to concentration of the expansion
liquid between 15 and 20 MPa
Concen-
Total
tration
sum of:
Biosol E
setting exp
0 %
0 30 %
50 %
0 35 %
75 %
0 45 %
100 %
0 50 %
therm exp
0 65 %
0 95 %
1 05 %
1 15 %
03.11.14 13:18