Troubleshooting

A system fault will be indicated by an acoustic signal and one of the follow-
ing fault codes on the main display:
Display Fault
E01 E
General system failure
E02 E
Memory failure
E03 E
Overheated coil
E04 E
not in use
E05 E
Temperature increase of
less than 1° every 15
seconds (or 1° every 30
seconds)
E06 E
Temperature probe not
connected (or defective)
E07 E
Failure during current
measurement
E08 E
Failure during communi-
cation with power printed
circuit board
E09 E
Overheated printed circuit
board
34
Action
Return IH 070/090 for repair.
Return IH 070/090 for repair.
Wait until the inductive coil cools.
Check the temperature probe connec-
tion. If the connection is OK, select
the 30 second interval as described
in section 6 or operate the heater in
TIME MODE.
Check the temperature probe.
Return IH 070/090 for repair.
Return IH 070/090 for repair.
Wait until the printed circuit board
cools.