Replacing Components; Instructions For Use - MBM FTBG74A Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67
Before proceeding see chap. 2
1. Remove the container
2. Remove the instrument panel and
knobs
REPLACING THERMOCOUPLE
Unscrew the thermocouple from the
1.
tap
Unscrew the thermocouple from the
2.
pilot
Fit the new thermocouple and screw
3.
the connections
REPLACING IGNITION SPARK
Remove the high-voltage cable of
1.
the spark
Unscrew the nut
2.
Replace the spark new
3.
Connect the high voltage cable
4.
REPLACING PIEZO
Remove the cable from the piezo
1.
electric ignitor
Remove the ignitor to replace
2.
Fit the new piezo electric ignitor
3.
GAS THERMOSTAT REPLACEMENT
1. Remove the fixing clip
LOCATION OF MAIN COMPONEN-
TS - see SECT. IMAGES - REF. m)
The layout of the figures is purely indi-
cative and can undergo variations.
1. Thermostat knob (see Knobs, keys
and indicator light modes and fun-
ctions).
2. Piezoelectric button (see Knobs,
keys and indicator light modes and
functions).
3. Hotplate.
4. Cooking oil/grease collection container.
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.

REPLACING COMPONENTS

2. Remove the bulb from the support
3. Unscrew the gas inlet and outlet
connections
4. Unscrew the thermocouple
5. Install the new thermostat
6. Check the by-pass screw (for the
reduce heat input / see previous para-
graph and Technical Data Tables)
7. Replace the connections and the
removed parts
BURNER REPLACEMENT
1. Disconnect the power supply
2. Remove the thermostat bulb
3. Remove the bulb holders
4. Unscrew the fixing screws of the pi-
lot system and remove it
5. Remove the combustion chamber
cover
6. Remove the burner
7. Place the new burner and reassem-
ble what was previously removed (co-
ver, pilot unit, etc.)
8. Replace the connections
Check the gas voltage with the
special tools and replace the par-
ts removed in the correct order

INSTRUCTIONS FOR USE

KNOBS, KEYS AND INDICATOR
LIGHT MODES AND FUNCTIONS
see SECT. IMAGES - REF. n).
The layout of the keys in the figures is
purely indicative and can be subject to
variations.
THERMOSTAT KNOB (GAS).
1
(GAS). It performs three diffe-
rent functions:
1. Igniting the pilot light and burner.
2. Temperature regulation.
3. Turning the appliance off.
- 15 -