DeWalt D55394 Manual De Instrucciones página 10

Compresor de aire eléctrico portátil con ruedas para contratistas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

AIr IntAkE fIltEr
The filter (A) is designed to clean air entering the pump.
To ensure the pump continually receives a clean, cool
and dry air supply the filter must always be clean and
the filter intake must be free from obstructions.
AIr tAnk DrAIn VAlVE
The drain valve (J) is used to remove
moisture from the air tank after the air
compressor is shut off.
AIr tAnk PrEssurE GAuGE
The air tank pressure gauge (D)
indicates air pressure in the air tank.
rEGulAtED PrEssurE GAuGE
The regulated pressure gauge (E)
indicates the air pressure available at
the outlet side of the regulator. This
pressure is controlled by the regulator and is always less or equal to
the air tank pressure.
rEGulAtor
The regulator knob (F) controls the air pressure coming from the air
tank.
to Adjust regulator:
1. Pull regulator knob (F) out.
2. Turn knob clockwise to increase regulated pressure and
counterclockwise to decrease regulated pressure.
3. When desired pressure is shown on the regulated pressure
gauge push knob in to lock.
Motor oVErloAD ProtECtor
A
The motor has a thermal overload protector. If the motor overheats
for any reason, the overload protector will shut off the motor. The
motor must be allowed to cool down before restarting. To restart:
1. Set the On/Off switch to OFF and unplug unit.
2. Allow the motor to cool.
J
3. Depress the red reset button on the motor.
4. Plug the power cord into the correct branch circuit receptacle.
5. Set the On/Off switch to ON/AUTO position.
InSTALLATIon
Assembly (Fig. 1)
InstAllInG HosEs
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
D
F
when installing or disconnecting to prevent hose whip.
E
1. Ensure regulated pressure gauge reads 0 psi.
2. Apply sealant tape to hose threads.
3. Assemble hose to air outlet (G). IMPortAnt: Do not assemble
splitters directly to the air outlet (G).
notE: Assembling quick connect bodies to air outlet (G) and quick
connect plugs to hose ends make connecting and disconnecting
hoses simple and easy. Quick connect bodies and plugs are
available for purchase from your local dealer or authorized service
center.
DIsConnECtInG HosEs
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Remove hose(s) from air outlet(s) (G).
10

Publicidad

Tabla de contenido
loading

Tabla de contenido