Operating Instructions; Compressor Start And Stop; Pressure Switch/Power Switch; Safety Valve - VITO PRO-POWER VICOC200A Manual De Instrucciones

Compresor con correa
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
hose connecting accessory into the
quick connections;
These quick connection valves allow
outlet pressure regulation.
4. OPERATING
INSTRUCTIONS
This type of compressor is frequently
used in civil works, repairing shops
and industries. It provides compressed
air for several equipments, such as air/
painting guns and pneumatic tools.
When using the compressor, its user
must consider some safety measures:
� Do not touch the cylinders gasket,
cooling fins and compressed air
pipes, once these elements reach high
temperatures while operating. After
stopping the compressor wait some
minutes until the parts cool down;
� Never place any flammable, nylon or
cloth objects nearby and/or over the
compressor;
� The pipes or hoses connected to
the compressor must have the same
characteristics of flow and pressure.
At least they must be equal to the
compressor's technical specifications;
� Never switch on the compressor if the
air filter isn't assembled;
� Never change the safety valve neither
the tank.
� If there are any ball-type shutoff valves
in the compressor connections to the
stationary system, they must be opened
slowly. Never open the valve quickly
once it will release energy that may
damage equipments or tools;
� The compressor mustn't be switched
on
without
the
belt
otherwise it may cause physical or
goods damages;
� If the compressor is going to be used
on painting works, its user must be over
36
10m away from the equipment. It is
recommended to use the connection
hoses to work with enough distance
from the compressor;
� The compressor must only be set
into operation in environments with a
temperature between + 5°C e +45°C;
Before starting the compressor,
its user must ensure that all the
components are correctly assembled.
4.1 - COMPRESSOR START
AND STOP
After carrying out all the assembly and
installation procedures, the compressor
is ready to operate. The initiation should
be carried out right after the installation
respecting the following order:
1. Check the oil level through the display
(24) and plug in the power cord;
2. Pull the power switch (17) to switch
the engine on;
- The compressor will operate until
the tank is fully pressurized. It will then
shut down, after the tank reaches its
maximum pressure, displayed in the
pressure switch (16).
- When the engine shuts down, the
accumulated compressed air inside the
pipes between the compression pump
and the non-return valve is released.
This is the necessary condition to
prevent a restart with the engine in
effort. Therefore it prevents damages
and increases compressor's lifespan.
3. Press the power switch to stop the
engine and prevent an automatic start;
4. Open the condensates drain (26)
to drain the condensed water inside
the tank;
5. After draining out completely, close
protection,
the drain;
6. Connect the air guns and tools into
the quick connection valves (3) or into
the stationary system;
(FIG. F)
7. Pull the power switch to set the
compressor to operate;
- When turning the compressor ON,
if the tank pressure is inferior to the
minimum pressure indicated in the
pressure switch, the engine will start
immediately;
8. Check if there are any air leaks in
the pipes or connecting accessories.
If there aren't any tools or accessories
connected to the compressor or to the
distributing system and the compressor
starts systematically, it means that
there are leaks;
4.2 - PRESSURE SWITCH/
(FIG. G)
POWER SWITCH
The compressor's automatic operation
is controlled by the pressure switch
(16). The compressor starts when
the minimum and maximum pressure
values are reached, as long as the
power switch's button is pulled up.
The minimum and maximum pressure
are established from factory, do not
change them.
The power switch connected to the
pressure switch allows stopping the
compressor every time its user intends
to or in case of an emergency.

4.3 - SAFETY VALVE

The safety valve (28) is prepared to
trigger according to the compressed
air tank admissible pressure (25). If for
some reason the admissible pressure is
reached and the engine doesn't stop,
the safety valve shall open. It is not
allowed to adjust de safety valve or to
remove the plastic seal.
In order that the safety valve can
function correctly in case of need, it
must be activated frequently.
1. To make sure that the safety valve
works correctly, pull on the attached
ring. The air will be released loudly.
Then, loosen the ring.
(FIG. G)

Publicidad

Tabla de contenido
loading

Tabla de contenido