6. Install the cover to the back wall with the
materials.
Preparing the connection to
the outside air
If the appliance is installed in a room without sufficient
ventilation, you can install the connecting kit on the
appliance (supplied with the appliance) for the supply
of outside air. Some of the air inlets on the appliance
must then be plugged with the blanking material
provided.
The air supply tube has a diameter of 100mm. If the
tube is smooth, it may be no longer than 12m. If
accessories such as bends are used, the maximum
length (12m) must be reduced by 1m for each
accessory used.
Outside air connection via the floor
1. Make an opening in the floor (see Appendix 2,
Measurements, for the correct position of the
opening).
2. Hermetically close the air supply tube at the floor.
10
Installation
3. Install the connection collar on the bottom plate
and close the rear wall with the cover.
The guard is no 3 on the diagram.
Connection to outside air via the
rear of the appliance:
1. Make an opening in the wall (see Appendix 2,
Measurements, for the correct position of the
opening).
2. Hermetically close the air connection tube at the
wall.
3. Install the connection collar on the back wall and
close the opening in the bottom plate with the
cover.
The guard is no 4 on the diagram.