Installation
Warning
Interference due to electromagnetic sources is liable to
cause sudden compensatory movements of the axis.
Follow the installation procedure below in order to pre
vent this electromagnetic interference.
Connect the earth connection on the left−hand side of
the housing with low impedance (short cable with
large cross−sectional area) to the earth potential, if the
axis interface is not attached to an earthed machinery
frame.
Only with measuring system type MLO−POT−...−LWG:
For earthing, connect the earth strip (included with the
measuring system) to the flat plug of the measuring
system and to the earthing connection of the axis in
terface.
1
Measuring system
(here type
SPC−AIF−POT−LWG)
2
Earth strip (only
with measuring
system type
MLO−POT−...−LWG)
3
Earthing connection
16
Ì Ì Ì Ì
1 2
Ì Ì Ì Ì
Festo SPC−AIF−... 0506b English