Type (continued)
Valve output (MPYE−5−...)
Power supply
Output voltage
Potentiometer
(only SPC−AIF−POT and ...−LWG)
Reference voltage V
R
min
Digital measuring system
(only SPC−AIF−MTS)
V
OUT
Electromagnetic compatability
Interference emission
Resistance to interference
Oscillation and shock
Oscillation
Shock
3)
The component is intended for industrial usage
22
SPC−AIF−...
24 V (DC)
0 ... +10 V
+10 V
OUT
2.5 k
+24 V
Tested in accordance with
EN 61000−6−4 (industry)
Tested in accordance with
EN 61000−6−2 (industry)
Tested as per DIN/IEC 68/EN
60068 part 2−6;
0.35 mm path at 10...60 Hz
5 g acceleration at 60...150 Hz
Tested as per DIN/IEC 68/EN
60068 part 2−27; ± 30 g at 11 ms
duration; 5 shocks per direction
3)
3)