SFA SANIBEST Manual De Instalación página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
Warning: Ensure the electricity is turned OFF at the main
switch board before wiring to connector.
All work on cable and motor should only be carried out by
a qualified Saniflo servicing agent, as special tools are
required.
8
NORM
• SANIBEST
conforms to the European directives and
®
standards on electrical safety, electromagnetic compatibility
and building products. It conforms to EN 12050-3 (lifting
plant for wastewater containing faecal matter for limited
applications).
9
COMMISSIONING THE UNIT
Once electrical and plumbing connections have been made,
flush the WC once. The motor should run from 5 to
10 seconds to clear the waste (depending on the length and
height of the pipe run). If it runs for more than 30 seconds,
check that the discharge pipe is not kinked or blocked or
check that the non-return valve is correctly installed.
Flush the WC checking that all seals, and connections are
watertight. Check both the discharge pipework from the
unit, and the waste pipes from washbasin or shower.
There should be no dripping of water from the
WARNING:
WC cistern or taps. If there is, this will cause the unit to
activate repeatedly as it pumps the water away.
1 0
USAGE
A WC fitted with a SANIBEST
require any special maintenance.
The SANIBEST
will operate automatically as soon as the
®
required level of water enters the case.
WARNING:
The water authorities strongly discourage the
disposal of sanitary items such as condoms, tampons and
sanitary pads via a WC. Nowever, should such items be
flushed down a WC attached to SANIBEST
able to accept these items without blocking.
However, any such use lies outside the field of application, and
any damage caused to the unit due to maceration of these
foreign bodies, together with wipes, food products, hairs,
objects made of metal, wood or plastic, or solvents, acids and
other chemicals, lies outside the scope of the
guarantee.
1 1
CARE OF YOUR SANIBEST
In order to remove scale and clean the macerator and the bowl,
use a household descalent.
• Disconnect the macerator power,
• Pour an amount of descalent in the pan
• leave it to stand for 1 or 2 hours,
• Re-connect the macerator power,
• Rinse by operating the flushing system twice.
Carry out the operation once every 3 months on average, but
the frequency may need to be changed depending on the
hardness of the water.
pump/macerator does not
®
®
, the unit is
UNIT
®
FAULT FINDING/REMEDIES
1 2
For the most part any inconsistencies in the operation of the
unit will be minor and easily rectified. Please refer to the chart
below. If the problem cannot be easily remedied in this way.
Please call our Service organisation.
Warning - Always disconnect the electricity supply before
attempting any work on the SANIBEST
SYMPTOM
PROBABLES CAUSES
• The motor intermittently
• The WC cistern or taps are
activates
dripping
• The external non-return
valve is faulty
• Motor is surging and
• The air opening 26 of
water in the WC pan goes
the unit is blocked
down very slowly
• The motor operates
• The length or height of
normally, but continues to
the installation is over the
run for a long time
specification, or there are
too many bends/elbows
• The unit is blocked
• The motor does not
• The electrical supply is
activate
not active
• Problem with motor or
electrical chamber
• The motor hums, but
• The capacitor 38 or
does not run
motor is defective
REMOVAL
1 3
All work involving dismantling of the appliance must be
carried out by an approved repair agent
Any replacement of the power supply cable should only be
carried out by an authorised SANIFLO service engineer.
REMOVING THE UNIT
Disconnect the electricity supply
A
Turn off the water feed to the WC cistern. Bail out as much water
B
from the cistern as possible.
Remove discharge hose from elbow 21d . Remember that the
vertical head of water will run back
Disconnect the inlet and WC connection, as well as electric
supply and remove unit.
REMOVING THE MOTOR FROM THE CASE
Unscrew the 2 lid screws 33 (Torx T20).
C
Lift off the lid freeing the end lugs.
D
Unscrew the screw 33 holding the oval shaped electrical chamber
E
to the case.
Lift out the motor.
F
The metallic dome on top of the motor may be hot
so handle with care.
WARNING :
Do not activate the motor when 'dry'.
(otherwise support washers will be irreparably destroyed)
REMOVAL OF BLADES
Unscrew the 3 blade screws 12 .
G
Repair or exchange the blade assembly 5 .
H
RE-ASSEMBLY OF THE BLADES
Before re-assembly, ensure that the drive coupling
I
well pressed into the base of the pump
For easy replacement of the lid, lubricate the lid seal 2b
NOTE:
with liquid soap.
Do not reconnect the electrical power supply
until the re-installation is complete.
1 4
GUARANTEE
range is guaranteed for 2 years, subject to
®
SANIBEST
correct installation and usage.
®
REMEDIES
• Check the appropriate
washers / seals on the
cistern / taps etc
• Clean or replace the
non-return valve
• Replace the carbon filters
26b
• Check the installation
• Call a service engineer to
inspect the motor
• Restore the electrical
supply
• Call a service engineer to
inspect the motor
• Call a service engineer to
inspect the motor
is
4
.
11

Publicidad

Tabla de contenido
loading

Tabla de contenido