31 5.4 Fault Or Information Messages - Bosch FWA 46+ Serie Instrucciones De Uso Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
en |
44 | FWA 46xx + | Maintenance
5.4
Fault or information messages
5.4.1
Faults
Description / message
Possible cause
"No reference values."
Obstruction between the reference cameras.
"Measurement path inter-
Obstacle between camera and measurement
rupted"
board.
"No reference values or refe-
Obstruction between the reference cameras or
rence values not stable."
no stable reference values due for example to vi-
bration.
Fault message "Network
No connection between Ethernet switch and PC.
fault".
No connection between Power LAN and sensor.
"Problem with data trans-
Search for new communication paths for data
mission to sensor" displayed
transmission to sensors.
briefly on monitor.
"Measurement box not ac-
Re-establishment of connection to communica-
cessible" briefly displayed on
tion processor.
monitor.
"Measurement box not ac-
No connection between computer and communi-
cessible" constantly dis-
cation processor.
played on monitor.
Program crash.
Communication processor defective.
Fault message "Sensor incor-
Incorrect assignment of sensors
rectly assigned"
|
1 690 706 098
2017-11-27
Remedy / action
Make sure there is no obstruction between the reference ca-
meras.
Remove obstruction.
Shut down the PC, disconnect the FWA 46xx + from the mains
for 10 seconds and start up the PC again.
Make sure there is no obstruction between the reference came-
ras. Make sure the sensors/lifting platform are neither moving
nor vibrating. Switch off the vehicle engine if applicable to avoid
vibration at the platform or sensors.
Check cable connection.
Re-start wheel alignment unit.
Ignore the fault message.
Ignore the fault message.
Check wiring between computer and communication proces-
sor.
Shut down the PC, disconnect the FWA 46xx + from the mains
for 10 seconds and start up the PC again.
Inform customer service.
Terminate Aligner, select <Configuration of sensors> under <Ea-
sy3D Server> and perform assignment.
Robert Bosch GmbH

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido