Identification of the unit
TDA XX X
Accessories
FAF G4 intake filter
Contained in a special box, it is made of
synthetic fibre; the U-shaped frame is in
galvanised metal with two support nets in
galvanised wire
SM
Mixing chamber with G4 filter and
dampers
Galvanised steel box complete with two
air calibration dampers and opposed fins
in galvanised steel. The fins are moved
by nylon toothed wheels. Fin pitch
50mm; galvanised steel adjustment pin
with a diameter of 8mm. The dampers
are complete with manual adjustment
command but can also be motorised.
SR
Intake damper
Consisting of a frame with ribbed fins in
galvanised steel. The fins are moved by
nylon toothed wheels.
GM
Supply grille
Grille with double row of fins that can be
adjusted when emitting air into the room.
Can be installed directly on the equipment
(removing the flanges) or on the wall.
GA
Suction grille
With fins fixed at an angle of 45°; can
be installed directly on the equipment
(removing the flanges) or on the wall.
TABLE SHOWING ACCESSORY COMPATIBILITY:
TDA 09
FAF
FAF1
SM
SM1
SR
SR1
GM
GM5
GA
GA5
CMA
CMA5
BP
BP1
BR
BR1
PM
PM1
PX
PCT2
Selection, installation, use and maintenance manual
Version
3 : 3-row water coil
4 : 4-row water coil
E: 2-row direct expansion coil
X: Extractor (without coil)
Size
- 09
- 15
- 21
- 28
- 37
CMA Outer casing for grille
BP
After-heating 1-row water coil
positioned outside the unit
It is containedin a specific,thermally
isolated housing,and has a
one
row
louver
element.It
be installed exclusively on the air
discharge flange.
The powers are shown in Table N and are
relative to the nominal rate of air flow
and the delivered capacity.
BR
After-heating electric coil positioned
outside the unit
Electric coils of varying power are
provided for the various machines.
All the heaters contained in a suitable
housing, are made of modular armoured
e l e m e n t s , f i t t e d w i t h t w o s a f e t y
thermostats, one automatic, the other
calibrated at 100 °C with manual reset.
The reset enables the cover to be opened
to allow for inspection.
They must only be mounted down-line
to the finned elements, fixing them to
the discharge flange with the screws
provided.
PM
Supply plenum with circular start-
ups
TDA 15
TDA 21
FAF2
FAF3
SM2
SM3
SR2
SR3
GM6
GM7
GA6
GA7
CMA6
CMA7
BP2
BP3
BR2
BR3
PM2
PM3
PX
PCT2*
7
Air conditioning unit -
Double skinned panel in galvanised steel,
with injected polyurethane packing (40
kg/m
3
). It is fitted with galvanised steel
sheet spigots.
It is installed in replacement of the
must
discharge panel having rectangular
flanges using the same 4 self-tapping
screws.
The box is already complete with a filter
in synthetic fibres.
PX
Selector-only control panel
Wall mounted panel with three speed
selector switch to control the unit.
PCT2 Selector/thermostat/switch control
panel
It allows the control and regulation of
temperature.
On the panel there are:
- On-off switch;
- Knob temperature;
- Switch the fan speed at three positions
(a choice between the five available);
- Switch for cooling - heating water -
c o n t e m p o r a r y w a t e r h e a t i n g a n d
electrical resistance.
Being installed, you can choose between
running with the fan or set it in
operation.
TDA 28
FAF4
SM4
SR4
GM8
GA8
CMA8
BP4
BR4
PM4
TDA range
TDA 37
FAF4
SM5
SR4
GM8
GA8
CMA8
BP5
BR5
PM4