Relay Output; Start-Up - Italtecnica Mito Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

WARNING: An incorrect connection of the auxiliary contact could cause a short circuit in the
low voltage circuit and the consequential blowing of the fuse! Take care during connection.
 START-UP:
WARNING: At first start-up, avoi d operating the device for a long time without water to
avoid overheating the inverter! Fill the pump suction pipe before powering the system. If the
overheating protection triggers, fill the electric pump by connecting it directly to the power supply
to avoi d damaging the device!
Once all the electrical connections are made correctly, close the cover of the unit and connect the device
to the power supply.
Mito will start the pump automatically in order to fill the system.
If the pump does not turn, or produces anomalous vibrations, check that the pump and the capacitor are
correctly connected.
T o f a c i l i t a t e t h e f i l l i n g o f t h e e l e c t r i c p u m p , i t i s p o s s i b l e t o h o l d d o w n t h e " + " k e y o n t h e m a i n s c r e e n , t o
make the pump turn at maximum speed and without the dry run protection triggering.
After setting the device parameters, record them on the specific form that can be found at the end
of this manual for future reference and for warranty purposes.

RELAY OUTPUT

N.O.
500mA max.!
24
AUXILIARY INPUT
(FLOAT,
IRRIGATION
CONTROL UNIT,
ETC.)