2x Series Lightbar (with 3 or 4 Wires and Black Tops)
REPLACEMENT OF INBOARD AND END MODULES:
1. Disconnect main power.
2. Remove the four screws holding the problem module.
3. Remove connector by depressing the latch on rear of module and carefully pulling connector body from back of module.
4. Push module connector into replacement module ensuring locking latch is seated properly and connector is fully seated.
5. Align replacement module, ensuring wires are not pinched, and secure with the four screws.
6. Restore power to bar and test new module to ensure functionality.
NO OPERATION
NO TAKEDOWN LIGHTS
NO LIGHT OPERATION IN ONLY ONE MODULE
5.
TROUBLESHOOTING
Check input power and ground to lightbar, check signal wires for damage and/or opens.
Check Input power wire and verify a minimum of 10.0 Volts is present on the wire.
Check for blown fuse.
Verify configuration and make sure light modules are configured for takedown function.
Verify module is not configured as a takedown/worklight that is not configured to flash with
warning.
Verify connection to module inside lightbar.
Series 2Xwith3or4WiresAndBlackTops 1017