PRODUCT INSTRUCTIONS
The dehumidifi er is used to remove excessive moisture from the air. The resulting reduction in relative humidity
protects buildings and their contents from the adverse effects of excess humidity.
The environmentally friendly R290 is used as the refrigerant. R290 has no damaging infl uence on the ozone
layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because of its effi cient energy
properties, R290 is highly suitable as a coolant for this application. Special precautions must be taken into
consideration due to the coolant's high fl ammability.
SAFETY INSTRUCTIONS
- This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
- The unit is designed only for use with R-290(propane) gas as the designated refrigerant.
- THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD ATTEMPT
TO SERVICE!
- Do not discharge the refrigerant into the atmosphere.
- R-290 (propane) is fl ammable and heavier than air.
- It collects fi rst in low areas but can be circulated by the fans.
- If propane gas is present or even suspected, do not allow untrained personnel to attempt to fi nd the
cause.
- The propane gas used in the unit has no odor.
- The lack of smell does not indicate a lack of escaped gas.
- If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact
the local fi re department to advise them that a propane leak has occurred.
- Do not let any persons back into the store until the qualifi ed service technician has arrived and that
technician advises that it is safe to return to the store.
- No open fl ames, cigarettes or other possible sources of ignition should be used inside or in the vicinity
of the units.
- Component parts are designed for propane and non-incentive and non-sparking. Component parts
shall only be replaced with identical repair parts.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualifi ed persons in order to avoid a hazard.
- The appliance shall be disconnected from its power source during maintenance.
- Ensure the unit is far away from fi re, infl ammable, or explosive objects.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended
by the manufacture.
- The appliance shall be stored in a room without continuously operation sources (for example: open
fl ames, an operating gas appliance or an operating electric heater).
- The appliance shall be stored so as to prevent mechanical damage from occurring.
Do not piece or burn, even after use.
www.glaziar.com / info@glaziar.com