1975E-400A Control Panel; 1975E-400A Panel De Control - Atlanta Attachment Company AP26SEB24 Manual Del Usuario

Tabla de contenido

Publicidad

AAP26SEB47
1975E-400A
Control Panel
There must be an independent air supply to the
Control Panel (no tees or splices) from a main
line. This line should be able to maintain 4
CFM of air at 80 PSI.
If the Backlatch is not operating correctly:
(A) Turn off the air supply.
(B) Disconnect air line from the throat plate at the
vacuum valve.
(C) Clean any thread or trash from inside the
vacuum generator.
(D) Check all fittings and air lines for tightness and
air leaks.
(E) Check Throat Plate for holes in the tube or burrs
on the chaining finger.
16
Atlanta Attachment Company
770-963-7369 Fax: 770-963-7641
1975E-400A
Panel De Control
Tiene que haber un surtidor independiente de
presión de aire desde una linea principal al panel de
Control (no "T" o empalmes). Esta línea debe poder
mantener 4 Pies Cúbicos por Minuto (CFM) de
presión de aire a 80 PSI.
Si el Remate Automático no está operando
correctamente:
(A) Apague la presión de aire.
(B) Desconecte la manguera de presión de aire de la
plancha de la aguja a la válvula de succión.
(C) Limpie cualquier hilo o basura de dentro del
generador de vacío.
(D) Verifique que todos los accesorios y las
mangueras esten bien apretados y chequee por
escapes de aire.
(E) Chequee por orificios en el tubo de la Plancha de
la Aguja y por esquirlas en el dedo de encadenado.
Technical Manual

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ap26seb47

Tabla de contenido