Valve Stem
Spline Adapter
Stem Extension
5. Install the Cross Lever Handles
Remove and discard the plaster guards from each valve stem.
Install a spline adapter onto each valve stem.
Install a stem extension onto each spline adapter so the holes in
the extension are at the top, bottom and each side.
Secure the stem extension to each valve stem with a screw
(provided).
Slip a bonnet and O-ring over each stem extension. Thread a
bonnet onto each valve until snug against the finished wall.
Fit a center cap onto each stem extension so the same-sized holes
in each piece align.
All handle arms are shipped fully assembled. The long arms have
a center hole. Remove an end cap, washer, and sleeve from each
long arm.
Insert a long arm into the large hole of each center cap.
Reinstall the sleeve, washer, and end cap onto each long arm and
tighten.
Disassemble the two remaining handle arms by loosening the
short stud from the long stud of each arm. Be certain to separate
the two O-rings at the center of the handle arm so one remains
with each stud.
Insert the longer end of each long stud through the holes of each
center cap.
Kohler Co.
End Cap
Bonnet
Washer
O-Ring
Short
Screw
Stud
O-Ring
Center Cap
Long Stud
7
Sleeve
Long Arm
117124-2-A